EFFECTS OF LOCAL GEOMETRY AND FLUID-DYNAMICS ON REGIONAL PLATELET DEPOSITION ON ARTIFICIAL SURFACES

被引:79
作者
SCHOEPHOERSTER, RT
OYNES, F
NUNEZ, G
KAPADVANJWALA, M
DEWANJEE, MK
机构
[1] FLORIDA INT UNIV, DEPT IND ENGN, MIAMI, FL USA
[2] UNIV MIAMI, DEPT BIOMED ENGN, MIAMI, FL USA
[3] UNIV MIAMI, DEPT RADIOL, DIV NUCL MED, MIAMI, FL USA
来源
ARTERIOSCLEROSIS AND THROMBOSIS | 1993年 / 13卷 / 12期
关键词
FLUID DYNAMICS; REGIONAL PLATELET DEPOSITION; BLOOD-MATERIALS INTERACTION; STENOSIS; ANEURYSM; FLOW STREAMLINES; IN-111 PLATELET LABELING;
D O I
10.1161/01.ATV.13.12.1806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An important aspect of blood-material interactions is the activation, adhesion, and subsequent aggregation of blood platelets on the artificial surface, all of which are directly affected by local fluid dynamics. The objective of this work was to directly correlate changing local fluid dynamic conditions produced by various vessel geometries, including stenosis, aneurysm, and separate contraction and expansion geometries, with quantitative in vitro measurements of regional platelet deposition. We directly measured platelet deposition as a function of axial position along four Lexan flow chambers with axisymmetric models of these geometries using In-111-labeled platelets. Platelet deposition was maximum in observed areas of flow recirculation and reattachment and minimum in locations of high shear and separation. For the stenosis geometry, two distinct regions of increased platelet deposition were apparent, one proximal to and one distal to the stenosis throat. An approximately linear increase in platelet densities was produced in the aneurysm region, increasing in the direction of flow. Through a comparison of platelet deposition with local fluid streamline orientation, we have shown that platelet deposition is increased in certain areas due to the enhanced convective transport of platelets and blood cells to the vessel wall along locally curved streamlines with velocity components perpendicular to the vessel wall.
引用
收藏
页码:1806 / 1813
页数:8
相关论文
共 26 条
[1]  
ADDONIZIO VP, 1985, CARDIOL CLIN, V3, P431
[3]  
Baldwin J T, 1989, ASAIO Trans, V35, P429, DOI 10.1097/00002480-198907000-00083
[4]   THE EFFECT OF FLOW AND MASS-TRANSPORT IN THROMBOGENESIS [J].
BASMADJIAN, D .
ANNALS OF BIOMEDICAL ENGINEERING, 1990, 18 (06) :685-709
[5]   ADHESION OF PLATELETS TO ARTIFICIAL SURFACES - EFFECT OF RED-CELLS [J].
BRASH, JL ;
BROPHY, JM ;
FEUERSTEIN, IA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (03) :429-443
[6]  
CHANDRAN KB, 1988, ENCY MED DEVICES INS, V3, P1475
[7]  
DESHPANDE MD, 1983, ENG MECH, V109, P466
[8]  
Dewanjee M K, 1992, ASAIO J, V38, P88
[9]  
DEWANJEE MK, 1981, J NUCL MED, V22, P981
[10]  
DEWANJEE MK, 1985, RADIOLABELED CELLULA, P229