Objective: An investigation into the incidence and the clinical implication of discrepancies which may sometimes occur between invasive and non-invasive hemodynamic evaluation in septic patients. Design: A prospective, consecutive comparison. Setting: Department of Intensive Care Medicine at a University Hospital. Patients: 32 patients undergoing therapy for an episode of septic shock. Interventions: Conventional hemodynamic support (including volume expansion in all cases and inotropic support if necessary) required to obtain a stable hemodynamic status. Measurement and results: Cardiac output (thermodilution method), cardiac pressures (right heart catheterization) and left ventricular (LV) volumes (two-dimensional echocardiography) were simultaneously recorded. A comparison was thus made between both procedures, particularly concerning preload evaluation and assessment of left ventricular systolic function. Pulmonary artery occlusion pressure measurement was evidenced as an unreliable index of LV end-diastolic volume, determining preload. Assessment of LV systolic function by both methods was conflicting in 11 cases out of the 32. Conclusions: Frequent discrepancies between to invasive and non-invasive procedure were observed. The reasons for these discrepancies, including low vascular resistance, reduced LV compliance, and a possible overestimation of cardiac output by the thermodilution method, are examined in the light of data recorded. It was concluded that invasive hemodynamic evaluation by right heart catheterization in septic patients should be seriously questioned.
引用
收藏
页码:550 / 554
页数:5
相关论文
共 24 条
  • [1] INFLUENCE OF RIGHT VENTRICULAR FILLING PRESSURE ON LEFT-VENTRICULAR PRESSURE AND DIMENSION
    BEMIS, CE
    SERUR, JR
    BORKENHAGEN, D
    SONNENBLICK, EH
    URSCHEL, CW
    [J]. CIRCULATION RESEARCH, 1974, 34 (04) : 498 - 504
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] BIPLANE MEASUREMENTS OF LEFT AND RIGHT VENTRICULAR VOLUMES USING WIDE ANGLE CROSS-SECTIONAL ECHOCARDIOGRAPHY
    CHAUDRY, KR
    OGAWA, S
    PAULETTO, FJ
    HUBBARD, FE
    DREIFUS, LS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) : 391 - 391
  • [4] THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN
    DODGE, HT
    SANDLER, H
    BALLEW, DW
    LORD, JD
    [J]. AMERICAN HEART JOURNAL, 1960, 60 (05) : 762 - 776
  • [5] LEFT-VENTRICULAR PERFORMANCE IN SEPTIC SHOCK - REVERSIBLE SEGMENTAL AND GLOBAL ABNORMALITIES
    ELLRODT, AG
    RIEDINGER, MS
    KIMCHI, A
    BERMAN, DS
    MADDAHI, J
    SWAN, HJC
    MURATA, GH
    [J]. AMERICAN HEART JOURNAL, 1985, 110 (02) : 402 - 409
  • [6] ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY
    ERBEL, R
    SCHWEIZER, P
    LAMBERTZ, H
    HENN, G
    MEYER, J
    KREBS, W
    EFFERT, S
    [J]. CIRCULATION, 1983, 67 (01) : 205 - 215
  • [7] SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION
    GANZ, W
    SWAN, HJC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) : 241 - +
  • [8] DOBUTAMINE - A HEMODYNAMIC EVALUATION IN HUMAN SEPTIC SHOCK
    JARDIN, F
    SPORTICHE, M
    BAZIN, M
    BOUROKBA, A
    MARGAIRAZ, A
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (04) : 329 - 332
  • [9] SEPSIS-RELATED CARDIOGENIC-SHOCK
    JARDIN, F
    BRUNNEY, D
    AUVERT, B
    BEAUCHET, A
    BOURDARIAS, JP
    [J]. CRITICAL CARE MEDICINE, 1990, 18 (10) : 1055 - 1060
  • [10] DETECTION OF TRICUSPID REGURGITATION WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND PERIPHERAL VEIN INJECTIONS
    LIEPPE, W
    BEHAR, VS
    SCALLION, R
    KISSLO, JA
    [J]. CIRCULATION, 1978, 57 (01) : 128 - 132