ION-SENSITIVE FIELD-EFFECT TRANSISTOR AS A MONOVALENT CATION DETECTOR FOR ION CHROMATOGRAPHY AND ITS APPLICATION TO THE MEASUREMENT OF NA+ AND K+ CONCENTRATIONS IN SERUM

被引:18
作者
WATANABE, K
TOHDA, K
SUGIMOTO, H
EITOKU, F
INOUE, H
SUZUKI, K
NAKAMURA, S
机构
[1] KEIO UNIV,FAC SCI & TECHNOL,DEPT APPL CHEM,3-14-1 HIYOSHI,KOHOKU KU,YOKOHAMA,KANAGAWA 223,JAPAN
[2] SHIZUOKA UNIV,FAC ENGN,HAMAMATSU,SHIZUOKA 432,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 566卷 / 01期
关键词
D O I
10.1016/0378-4347(91)80115-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion-sensitive field effect transistor, which is a small potentiometric ion-sensing probe, was applied as a detector in the ion chromatography of alkali-metal cations. The cation-sensing transistor was prepared by coating the gate part of the probe to form a poly(vinyl chloride) matrix membrane containing tetranactin, which enables detection of alkali-metal ions such as Na+, K+, Rb+, and Cs+. To be able to analyse amounts less than 1-mu-l and make full use of the small ion-sensing probe, we constructed a miniature cation-exchange separation column (support 10-mu-m polystyrene) with a PTFE tube (20 mm x 1.5 mm I.D. x 2.1 mm O.D.). As an application of the system, Na+ and K+ concentrations in serum were determined. The analytical results for these two cations were good agreement with those obtained by flame photometry.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 17 条
[1]   SIMULTANEOUS DETERMINATION OF BROMIDE AND CHLORIDE IN NATURAL-WATERS BY ION-EXCHANGE CHROMATOGRAPHY AND DIRECT POTENTIOMETRY WITH AN ION-SELECTIVE ELECTRODE [J].
AKAIWA, H ;
KAWAMOTO, H ;
OSUMI, M .
TALANTA, 1982, 29 (08) :689-690
[2]   TECHNIQUE FOR DETERMINATION OF TRACE ANIONS BY COMBINATION OF A POTENTIOMETRIC SENSOR AND LIQUID-CHROMATOGRAPHY, WITH PARTICULAR REFERENCE TO DETERMINATION OF HALIDES [J].
FRANKS, MC ;
PULLEN, DL .
ANALYST, 1974, 99 (1181) :503-514
[3]   ION CHROMATOGRAPHY OF INORGANIC ANIONS WITH POTENTIOMETRIC DETECTION USING A METALLIC COPPER ELECTRODE [J].
HADDAD, PR ;
ALEXANDER, PW ;
TROJANOWICZ, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :363-374
[4]  
HADDAD PR, 1984, J CHROMATOGR, V295, P397
[5]  
ISHIBASHI N, 1985, ION SELECTIVE ELECTR, V4, P57
[6]   OPTIMIZATION OF ION CHROMATOGRAPHY USING COMMERCIALLY AVAILABLE DETECTION SYSTEMS AND SOFTWARE [J].
KEUKEN, MP ;
SLANINA, J ;
JONGEJAN, PAC ;
BAKKER, FP .
JOURNAL OF CHROMATOGRAPHY, 1988, 439 (01) :13-21
[7]  
KNOX JH, 1978, HIGH PERFORMANCE LIQ, P1
[8]   POTENTIOMETRIC DETECTOR FOR FAST HIGH-PERFORMANCE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY [J].
MANZ, A ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :74-79
[9]   PICOLITER CELL-VOLUME POTENTIOMETRIC DETECTOR FOR OPEN-TUBULAR COLUMN LC [J].
MANZ, A ;
SIMON, W .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (07) :326-330
[10]  
MUELLER H, 1985, ION SELECTIVE ELECTR, V4, P553