PROBLEMS ASSOCIATED WITH THE DETERMINATION OF PULMONARY VASCULAR-RESISTANCE

被引:13
作者
GORBACK, MS
机构
[1] Department of Anesthesiology, Duke University Medical Center, Durham, 27710
来源
JOURNAL OF CLINICAL MONITORING | 1990年 / 6卷 / 02期
关键词
Blood: flow; Lung: vascular resistance; Monitoring: pulmonary vascular resistance;
D O I
10.1007/BF02828288
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The presence of critical pressures in the pulmonary circulation complicates the traditional use of pulmonary vascular resistance (PVR). The recruitable nature of the pulmonary circulation violates a basic assumption of the PVR formula, that is, that the involved vessels arc rigid-walled. Flow through collapsible blood vessels is subject to the influence of critical opening pressures in addition to inflow and outflow pressures. As a result, PVR has a variable relationship to the Poiseuille resistance, approximating it better when zone 3 conditions predominate. In addition to being flow-dependent, PVR cannot easily distinguish among vasodilation, recruitment, and rheologie changes. PVR may be viewed as an index of steady-state power dissipation by the circulation, describing the relationship between power dissipation and flow, but it will still underestimate power dissipation by as much as 50%, since it cannot express oscillatory and kinetic power components. Laboratory data regarding the pulmonary circulation are predicted and explained by positing the existence of critical pressures in the pulmonary circulation and allow estimation of Poiseuille resistance. Unfortunately, clinical application of this approach is difficult owing to the necessity of generating pressure-flow plots under very stringent conditions. The clinical use of both pressure-flow and PVR-flow plots is impaired by shifting to different curves during hemodynamic manipulation. PVR must be interpreted in light of its considerable limitations. © 1990 Little, Brown and Company.
引用
收藏
页码:118 / 127
页数:10
相关论文
共 26 条
  • [1] Burton A.C., On the physical equilibrium of small blood vessels, Am J Physiol, 164, pp. 319-329, (1951)
  • [2] Mitzner W., Resistance of the pulmonary circulation, Clin Chest Med, 4, pp. 127-137, (1983)
  • [3] Nichol J., Girling P., Jerrard W., Et al., Fundamental instability of the small blood vessels and critical closing pressures in vascular beds, Am J Physiol, 164, pp. 330-344, (1951)
  • [4] Permutt S., Bromberger-Barnea B., Banc H.N., Alveolar pressure, pulmonary venous pressure, and the vascular waterfall, Med Thorac, 19, pp. 239-260, (1962)
  • [5] Permutt S., Riley L., Hemodynamics of collapsible vessel with tone: the vascular waterfall, J Appl Physiol, 18, pp. 924-932, (1963)
  • [6] Lopez-Muniz R., Stephens N.L., Bromberger-Barnea B., Et al., Critical closure of pulmonary vessels analyzed in terms of Starling resistor model, J Appl Physiol, 24, pp. 625-635, (1968)
  • [7] Zapol W.M., Snider M.T., Pulmonary hypertension in severe acute respiratory failure, N Engl J Med, 296, pp. 476-480, (1977)
  • [8] Zapol W.M., Trelstad R.L., Snider M.T., Et al., Pathophysiologic pathways of the adult respiratory distress syndrome, Care of the critically ill patient, pp. 341-358, (1983)
  • [9] McGregor M., Sniderman A., On pulmonary vascular resistance: the need for more precise definition, Am J Cardiol, 55, pp. 217-221, (1985)
  • [10] Conrad W.A., Pressure-flow relationships in collapsible tubes, IEEE Trans Biomed Eng, 16, pp. 284-295, (1969)