THE CORRECTION OF COAGULOMETER EFFECTS ON INTERNATIONAL NORMALIZED RATIOS - A MULTICENTER EVALUATION

被引:55
作者
POLLER, L [1 ]
THOMSON, JM [1 ]
TABERNER, DA [1 ]
CLARKE, DK [1 ]
机构
[1] WITHINGTON HOSP,UK REFERENCE LAB ANTICOAGULANT REAGENTS & CONTROL,MANCHESTER,LANCS,ENGLAND
关键词
PROTHROMBIN TIME; COAGULOMETER; INTERNATIONAL NORMALIZED RATIO (INR); ORAL ANTICOAGULANT CONTROL;
D O I
10.1111/j.1365-2141.1994.tb03260.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
One hundred and twenty-nine centres in the U.K. participated in a study to test the reliability of the three methods of correction for coagulometer effects on international normalized ratios (INR). Results from 37 centres which tested three warfarinized plasmas by the manual method were taken as the 'true' INR for the assessment of coagulometers. 63 centres (11 manual and 52 using coagulometers) determined their local International Sensitivity Index (ISI) in a calibration exercise. This was performed with a set of 20 lyophilized plasma calibrants with certified manual prothrombin times for the thromboplastin used in the study. The following methods of INR derivation were compared by assessing the percentage deviation from the three INK values established by 37 manual users: I. No coagulometer correction, i.e. (local PT/reference manual normal PT)(manual ISI) . II. Coagulometer ratio correction, i.e. (local coagulometer PT/local coagulometer MNPT)(manual ISI) . III. Local system ISI, i.e. (local coagulometer PT/local coagulometer MNPT)(local system ISI) . IV. System ISI, i.e. (local coagulometer PT/local coagulometer MNPT)(system ISI) . The local system ISI with the plasma calibrants (method III) gave the most reliable correction (mean deviation from 'true' INR 4.87%). The method which gave the least was with the coagulometer ratio correction, i.e. the manual ISI and local coagulometer MNPT (mean 11.25%). The system ISI tested with ACL coagulometers gave less correction than the local ISI calibration. The local system calibration with lyophilized plasmas also avoids some of the constraints on conventional thromboplastin calibrations.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 10 条
[1]   ASSESSMENT OF VALUE OF CALIBRATED LYOPHILIZED PLASMAS TO DETERMINE INTERNATIONAL SENSITIVITY INDEX FOR COAGULOMETERS [J].
CLARKE, K ;
TABERNER, DA ;
THOMSON, JM ;
MORRIS, JA ;
POLLER, L .
JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (01) :58-60
[2]   COMPARISON OF 2 AUTOMATED COAGULOMETERS AND THE MANUAL TILT-TUBE METHOD FOR THE DETERMINATION OF PROTHROMBIN TIME [J].
DANGELO, A ;
SEVESO, MP ;
DANGELO, SV ;
GILARDONI, F ;
MACAGNI, A ;
MANOTTI, C ;
BONINI, P .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (03) :321-328
[3]   ORAL ANTICOAGULANTS - MECHANISM OF ACTION, CLINICAL EFFECTIVENESS, AND OPTIMAL THERAPEUTIC RANGE [J].
HIRSH, J ;
DALEN, JE ;
DEYKIN, D ;
POLLER, L .
CHEST, 1992, 102 (04) :S312-S326
[4]  
POGGIO M, 1989, THROMB HAEMOSTASIS, V62, P868
[5]   EFFECT OF AUTOMATION ON PROTHROMBIN TIME TEST IN NEQAS SURVEYS [J].
POLLER, L ;
THOMSON, JM ;
TABERNER, DA .
JOURNAL OF CLINICAL PATHOLOGY, 1989, 42 (01) :97-100
[6]   LABORATORY CONTROL OF ORAL ANTICOAGULANTS [J].
POLLER, L .
BRITISH MEDICAL JOURNAL, 1987, 294 (6581) :1184-1184
[7]  
RAY MJ, 1990, THROMB HAEMOSTASIS, V63, P424
[8]  
Schmidt Nico A, 1989, CLIN CHEM, V355, P840
[9]   AUTOMATION AND PROTHROMBIN TIME - A UNITED-KINGDOM FIELD-STUDY OF 2 WIDELY USED COAGULOMETERS [J].
THOMSON, JM ;
TABERNER, DA ;
POLLER, L .
JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (08) :679-684
[10]  
1990, J CLIN PATHOL, V43, P177