A METHOD TO COMPENSATE FOR LIGHT ATTENUATION WITH DEPTH IN 3-DIMENSIONAL DNA IMAGE CYTOMETRY USING A CONFOCAL SCANNING LASER MICROSCOPE

被引:23
作者
LILJEBORG, A [1 ]
CZADER, M [1 ]
PORWIT, A [1 ]
机构
[1] KAROLINSKA HOSP, DEPT PATHOL, S-10401 STOCKHOLM, SWEDEN
关键词
CONFOCAL; MICROSCOPY; COMPENSATION; LIGHT ATTENUATION; HISTOSTACK; DNA IMAGE CYTOMETRY;
D O I
10.1111/j.1365-2818.1995.tb03540.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A method to compensate for attenuation of detected light with increased depth of the collected optical section, and its application in three-dimensional (3-D) DNA image cytometry is described. The method is based on studying the stack of 2-D histograms that can be formed from each consecutive pair of sections in a stack of optical serial sections. An attenuation factor is calculated interactively and a new compensated section series is computed. Formalin-fixed paraffin-embedded rat tissue was stained with propidium iodide, Each cell nucleus is extracted by thresholding and its total intensity is calculated. The coefficient of variation (CV) of the total intensity of all cells Tn each stack is computed. For comparison the CV of the same cells is computed in the uncompensated stacks. This study shows a significantly lower CV for the compensated data, thus contributing to the accuracy of DNA quantification in 3-D DNA image cytometry.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 1990, FLOW CYTOMETRY SORTI
[2]  
ASLUND N, 1992, P SOC PHOTO-OPT INS, V1660, P221, DOI 10.1117/12.59554
[3]  
AUER GU, 1980, ANAL QUANT CYTOL, V2, P161
[4]  
LILJEBORG A, 1993, NEUROPROTOCOLS, V2, P150
[5]  
LOOK AT, 1985, BLOOD, V65, P1079
[6]   THE PROGNOSTIC-SIGNIFICANCE OF DNA MEASUREMENTS IN ENDOMETRIAL CARCINOMA [J].
MOBERGER, B ;
AUER, G ;
FORSSLUND, G ;
MOBERGER, G .
CYTOMETRY, 1984, 5 (04) :430-436
[7]   3-DIMENSIONAL DNA IMAGE CYTOMETRY BY CONFOCAL SCANNING LASER MICROSCOPY IN THICK TISSUE BLOCKS [J].
RIGAUT, JP ;
VASSY, J ;
HERLIN, P ;
DUIGOU, F ;
MASSON, E ;
BRIANE, D ;
FOUCRIER, J ;
CARVAJALGONZALEZ, S ;
DOWNS, AM ;
MANDARD, AM .
CYTOMETRY, 1991, 12 (06) :511-524
[8]   AN FFT-BASED METHOD FOR ATTENUATION CORRECTION IN FLUORESCENCE CONFOCAL MICROSCOPY [J].
ROERDINK, JBTM ;
BAKKER, M .
JOURNAL OF MICROSCOPY-OXFORD, 1993, 169 :3-14
[9]   UNSUPERVISED NOISE REMOVAL ALGORITHMS FOR 3-DIMENSIONAL CONFOCAL FLUORESCENCE MICROSCOPY [J].
ROYSAM, B ;
BHATTACHARJYA, AK ;
SRINIVAS, C ;
SZAROWSKI, DH ;
TURNER, JN .
MICRON AND MICROSCOPICA ACTA, 1992, 23 (04) :447-461
[10]   ALGORITHMS FOR AUTOMATED CHARACTERIZATION OF CELL-POPULATIONS IN THICK SPECIMENS FROM 3-D CONFOCAL FLUORESCENCE MICROSCOPY DATA [J].
ROYSAM, B ;
ANCIN, H ;
BHATTACHARJYA, AK ;
CHISTI, MA ;
SEEGAL, R ;
TURNER, JN .
JOURNAL OF MICROSCOPY-OXFORD, 1994, 173 :115-126