VENIPUNCTURE FOR CALCIUM ASSAYS - SHOULD WE STILL AVOID THE TOURNIQUET

被引:10
作者
MCMULLAN, AD [1 ]
BURNS, J [1 ]
PATERSON, CR [1 ]
机构
[1] UNIV DUNDEE,NINEWELLS HOSP & MED SCH,DEPT BIOCHEM MED,DUNDEE DD1 9SY,SCOTLAND
关键词
D O I
10.1136/pgmj.66.777.547
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Blood was collected by venepuncture from nine healthy subjects over a ten minute period before applying a standard tourniquet, and over a ten minute period afterwards. Plasma ionised calcium was unaltered by the tourniquet, whereas total calcium, total protein and albumin in serum increased modestly. However, there was no effect on total calcium adjusted for albumin. Even without albumin adjustment the change in total calcium was negligible within one minute of the application of the tourniquet. We consider that in ordinary clinical practice, there is no need to perform venepuncture for calcium assays without a tourniquet.
引用
收藏
页码:547 / 548
页数:2
相关论文
共 9 条
[1]   THE ADJUSTED SERUM-CALCIUM CONCEPT - A REAPPRAISAL [J].
ASHBY, JP ;
WRIGHT, DJ ;
RINSLER, MG .
ANNALS OF CLINICAL BIOCHEMISTRY, 1986, 23 :533-537
[2]   THE MEASUREMENT OF IONIZED CALCIUM IN BLOOD-PLASMA [J].
BUCKLEY, BM ;
RUSSELL, LJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :447-465
[3]   CORRELATION BETWEEN SERUM IONIZED CALCIUM AND SERUM-ALBUMIN CONCENTRATIONS IN 2 HOSPITAL POPULATIONS [J].
BUTLER, SJ ;
PAYNE, RB ;
GUNN, IR ;
BURNS, J ;
PATERSON, CR .
BRITISH MEDICAL JOURNAL, 1984, 289 (6450) :948-950
[4]   THE CLINICAL-VALUE OF IONIZED CALCIUM ASSAYS [J].
GRAY, TA ;
PATERSON, CR .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :210-219
[5]  
HOPE RA, 1985, OXFORD HDB CLIN MED, P572
[6]  
IQBAL SJ, 1988, LANCET, V2, P1477
[7]   MEASURING SERUM-CALCIUM [J].
KANIS, JA ;
YATES, AJP .
BRITISH MEDICAL JOURNAL, 1985, 290 (6470) :728-729
[8]  
PAYNE RB, 1989, LANCET, V1, P562
[9]  
ZILVA JF, 1988, CLIN CHEM DIAGNOSIS, P447