FINITE-ELEMENT MODELS OF THORACIC CONDUCTIVE ANATOMY - SENSITIVITY TO CHANGES IN INHOMOGENEITY AND ANISOTROPY

被引:17
作者
KARLON, WJ
LEHR, JL
EISENBERG, SR
机构
[1] BRIGHAM & WOMENS HOSP, DEPT BIOMED ENGN, BOSTON, MA 02215 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA USA
[3] HARVARD UNIV, SCH PUBL HLTH, BOSTON, MA 02115 USA
[4] BOSTON UNIV, DEPT BIOMED ENGN, BOSTON, MA 02215 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/10.335838
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A moderately detailed 3-D finite element model of the conductive anatomy of a canine thorax was used to examine the sensitivity of the results obtained during simulated transthoracic defibrillation to variations in skeletal muscle anisotropy and differing degrees of model inhomogeneity. Our results suggest that the myocardial current density distribution is not particularly sensitive to the method used to model skeletal muscle anisotropy. However, anisotropy variations caused defibrillation parameters such as paddle to paddle impedance and threshold current to change by as much as 50%. We found a greater sensitivity in the myocardial current density and the defibrillation parameters to variations in model inhomogeneity. The changes observed in both depended substantially on paddle placement. This sensitivity to paddle placement highlights the difficulty in predicting how a reduction in anatomical detail will affect the myocardial current density distribution. In general, we found the defibrillation parameters to be more sensitive than the myocardial current density distribution to the variations in anatomical detail we examined.
引用
收藏
页码:1010 / 1017
页数:8
相关论文
共 21 条
[1]
OPTIMAL ELECTRODE CONFIGURATIONS FOR EXTERNAL CARDIAC PACING AND DEFIBRILLATION - AN INHOMOGENEOUS STUDY [J].
BENFAHY, J ;
KIM, YM ;
ANANTHASWAMY, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (09) :743-748
[2]
A VOLUME CONDUCTOR MODEL OF THE THORAX FOR THE STUDY OF DEFIBRILLATION FIELDS [J].
CLAYDON, FJ ;
PILKINGTON, TC ;
TANG, ASL ;
MORROW, MN ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) :981-992
[3]
FUNDAMENTAL CRITERIA UNDERLYING THE EFFICACY AND SAFETY OF DEFIBRILLATING CURRENT WAVEFORMS [J].
GEDDES, LA ;
NIEBAUER, MJ ;
BABBS, CF ;
BOURLAND, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (02) :122-130
[4]
SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[5]
CURRENT CONCEPTS FOR SELECTING THE LOCATION, SIZE AND SHAPE OF DEFIBRILLATION ELECTRODES [J].
IDEKER, RE ;
WOLF, PD ;
ALFERNESS, C ;
KRASSOWSKA, W ;
SMITH, WM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :227-&
[6]
EFFECTS OF PADDLE PLACEMENT AND SIZE ON DEFIBRILLATION CURRENT DISTRIBUTION - A 3-DIMENSIONAL FINITE-ELEMENT MODEL [J].
KARLON, WJ ;
EISENBERG, SR ;
LEHR, JL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (03) :246-255
[7]
QUALITATIVE EFFECTS OF THORACIC RESISTIVITY VARIATIONS ON INTERPRETATION OF ELECTROCARDIOGRAMS - LOW RESISTANCE SURFACE LAYER [J].
MCFEE, R ;
RUSH, S .
AMERICAN HEART JOURNAL, 1968, 76 (01) :48-&
[8]
EFFECTS OF CARDIAC CONFIGURATION, PADDLE PLACEMENT AND PADDLE SIZE ON DEFIBRILLATION CURRENT DISTRIBUTION - A FINITE-ELEMENT MODEL [J].
RAMIREZ, IF ;
EISENBERG, SR ;
LEHR, JL ;
SCHOEN, FJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (06) :587-594
[9]
Rush S, 1969, J Electrocardiol, V2, P331, DOI 10.1016/S0022-0736(69)80003-8
[10]
SCHMIDT J, 1992, CRIT REV BIOMED ENG, V20, P121