RISKS AND BENEFITS OF USING MARLEX MESH IN CHEST-WALL RECONSTRUCTION

被引:60
作者
KROLL, SS
WALSH, G
RYAN, B
KING, RC
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT THORAC SURG,HOUSTON,TX 77030
[2] BAYLOR COLL MED,DIV PLAST SURG,HOUSTON,TX 77030
关键词
D O I
10.1097/00000637-199310000-00003
中图分类号
R61 [外科手术学];
学科分类号
摘要
The records of 101 patients who had undergone chest wall reconstruction both with and without stabilization of the chest wall by Marlex mesh were reviewed to see if Marlex reduced ventilator dependence and hospital stay, and to determine whether the use of Marlex was associated with any increased risk of infection. In 40 patients in whom Marlex was used, the mean number of days on postoperative ventilator support was 0.8, and mean hospital stay was 9.7 days. In 61 patients in whom Marlex was not used, the mean number of days on ventilator support was 4.9, and mean hospital stay was 17.5 days. These differences were statistically significant (p = 0.03, p = 0.006). Two patients in the Marlex-stabilized group (5%) developed wound infections, but these were preceded by ischemic necrosis of overlying flaps. None of the patients without Marlex developed wound infections. That difference was not statistically significant. We conclude that the use of Marlex in chest wall reconstruction does not significantly increase the risk of wound infection, provided that overlying tissues are properly vascularized and remain viable, and that synthetic mesh does improve chest wall stability and reduce ventilator dependence and overall hospital stay.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 13 条
[1]  
ANTIA N H, 1971, British Journal of Plastic Surgery, V24, P15, DOI 10.1016/S0007-1226(71)80004-8
[2]   ESTABLISHMENT OF NORMAL RANGES OF LASER DOPPLER BLOOD-FLOW IN AUTOLOGOUS TISSUE-TRANSPLANTS [J].
CLINTON, MS ;
SEPKA, RS ;
BRISTOL, D ;
PEDERSON, WC ;
BARWICK, WJ ;
SERAFIN, D ;
KLITZMAN, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (02) :299-309
[3]   PATTERNS OF VASCULAR ANASTOMOSES VS SUCCESS OF FREE GROIN FLAP TRANSFERS [J].
GOODSTEIN, WA ;
BUNCKE, HJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1979, 64 (01) :37-40
[4]  
HEDEN PG, 1985, MICROSURG, V6, P2
[5]   LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD-FLOW [J].
HOLLOWAY, GA ;
WATKINS, DW .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1977, 69 (03) :306-309
[6]   THE LASER DOPPLER FLOWMETER FOR MICRO-VASCULAR MONITORING - A PRELIMINARY-REPORT [J].
JONES, BM ;
MAYOU, BJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1982, 35 (02) :147-149
[7]   SECONDARY CRITICAL ISCHEMIA TIME OF EXPERIMENTAL SKIN FLAPS [J].
KERRIGAN, CL ;
ZELT, RG ;
DANIEL, RK .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 74 (04) :522-524
[8]  
MALT RA, 1964, JAMA-J AM MED ASSOC, V189, P716
[9]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[10]  
RIVA C, 1972, INVEST OPHTH VISUAL, V11, P936