Experiences from operation of different expansion devices for application in domestic micro CHP

被引:12
作者
Mikielewicz, Dariusz [1 ]
Mikielewicz, Jaroslaw [2 ]
Wajs, Jan [1 ]
机构
[1] Gdansk Univ Technol, Fac Mech Engn, Inst Power Engn & Turbomachinery, Narutowicza 11-12, PL-80952 Gdansk, Poland
[2] Polish Acad Sci, Szewalski Inst Fluid Flow Machinery, PL-80231 Gdansk, Poland
关键词
Mcro CHP; Expansion devices; Central heating;
D O I
10.2478/v10173-010-0023-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the paper presented are experiences from operation of three different expansion devices for possible implementation in the domestic micro CHP. These were the modified scroll expander and two designs based on the variable working chamber volume pneumatic devices. Experiments showed the superiority of both "pneumatic devices" over the scroll expander, indicating the possible internal efficiencies in the range of 61 82Such efficiencies are very attractive, especially at the higher end of that range. The volume of these devices is much smaller than the scroll expander which makes it again more suitable for a domestic micro CHP. Small rotational velocities enable to conclude that connection to electricity grid will also be simpler in the case of "pneumatic devices". The "pneumatic devices" under scrutiny here could be an alternative to the typical vapour turbine in the ORC cycle, which is in the process of development at the IFFM.
引用
收藏
页码:3 / 13
页数:11
相关论文
共 4 条
[1]  
[Anonymous], 2007, REFPROP 8 0
[2]  
Mikielewicz Dariusz, 2008, Archives of Thermodynamics, V29, P109
[3]   A thermodynamic criterion for selection of working fluid for subcritical and supercritical domestic micro CHP [J].
Mikielewicz, Dariusz ;
Mikielewicz, Jarostaw .
APPLIED THERMAL ENGINEERING, 2010, 30 (16) :2357-2362
[4]  
Mikielewicz Jaroslaw, 2009, Archives of Thermodynamics, V30, P3