DEVELOPMENT OF 3-D DETECTOR SYSTEM FOR POSITRON CT

被引:44
作者
SHIMIZU, K
OHMURA, T
WATANABE, M
UCHIDA, H
YAMASHITA, T
机构
关键词
BIOMEDICAL ENGINEERING - Computerized Tomography - Computer simulation - Electron tubes; Photomultiplier - GAMMA RAYS - Absorption - Scintillation counters;
D O I
10.1109/23.12818
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A detector composed of a bundle of BGO (bismuth germanate) pillars and positron-sensitive photomultiplier tubes is proposed. This detector has the ability to provide 3-D position information on gamma -ray absorption in the scintillator. It is expected that the use of this detector for positron-emission tomography (PET) will result in high spatial resolution and sensitivity. In particular, uniform and high spatial resolution over the entire field of view can be obtained because of the detector's ability to detect the depth of interaction of the gamma -rays in the scintillator. The fundamental characteristics were investigated by both experiment and simulation, and the results are discussed.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 13 条
[1]   INITIAL CHARACTERIZATION OF A BGO-PHOTODIODE DETECTOR FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY [J].
DERENZO, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :620-626
[2]   INITIAL RESULTS FROM THE DONNER-600 CRYSTAL POSITRON TOMOGRAPH [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, A ;
UBER, D ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :321-325
[4]   POSITION-SENSITIVE PHOTOMULTIPLIER TUBES FOR SCINTILLATION IMAGING [J].
KUME, H ;
MURAMATSU, S ;
IIDA, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :359-363
[5]   ON THE USE OF TAPERED BISMUTH-GERMANATE CRYSTALS IN POSITRON EMISSION TOMOGRAPHY [J].
LUPTON, LR ;
KELLER, NA ;
THOMPSON, CJ ;
ANDERSON, LL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :361-368
[6]   A MODULAR SCINTILLATION CAMERA FOR USE IN NUCLEAR-MEDICINE [J].
MILSTER, TD ;
SELBERG, LA ;
BARRETT, HH ;
EASTON, RL ;
ROSSI, GR ;
ARENDT, J ;
SIMPSON, RG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :578-580
[7]   PETT-IV - DESIGN ANALYSIS AND PERFORMANCE-CHARACTERISTICS [J].
MULLANI, NA ;
HIGGINS, CS ;
HOOD, JT ;
CURRIE, CM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) :180-183
[8]   A LARGE POSITION-SENSITIVE NEUTRON DETECTOR [J].
NETTER, P ;
LASSEN, L ;
SCHRECK, R ;
GEMMEKE, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3) :165-174
[9]   DESIGN OF AN EFFICIENT POSITION-SENSITIVE GAMMA-RAY DETECTOR FOR NUCLEAR-MEDICINE [J].
ROGERS, JG ;
SAYLOR, DP ;
HARROP, R ;
YAO, XG ;
LEITAO, CVM ;
PATE, BD .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (10) :1061-1090
[10]   DEVELOPMENT OF A HIGH-RESOLUTION POSITRON CT FOR ANIMAL STUDIES [J].
TOMITANI, T ;
NOHARA, N ;
MURAYAMA, H ;
YAMAMOTO, M ;
TANAKA, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :822-825