COMPATIBILITY OF INTRAOCULAR LENSES WITH BLOOD AND CONNECTIVE-TISSUE CELLS MEASURED BY CELLULAR-DEPOSITION AND INFLAMMATORY RESPONSE INVITRO

被引:17
作者
JOO, CK
KIM, JH
机构
[1] Department of Ophthalmology, Catholic University Medical College, Seoul
关键词
CHEMILUMINESCENCE; COMPATIBILITY; HEPARIN SURFACE MODIFICATION; POLYHYDROXYETHYL METHACRYLATE; POLY(METHYL METHACRYLATE); SCANNING ELECTRON MICROSCOPY; SILICONE; SURFACE-MODIFIED INTRAOCULAR LENSES;
D O I
10.1016/S0886-3350(13)80900-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Injection molded poly(methyl methacrylate) (IM-PMMA), lathe-cut PMMA (LC-PMMA), heparin surface modified PMMA (HSM-PMMA), silicone, and polyhydroxyethyl methacrylate (polyHEMA) intraocular lenses (IOLs) were incubated with platelets, granulocytes, mouse macrophage-like RAW 264.7 cells and mouse fibrosarcoma L929 cells to examine their compatibility. The number of cells attached to the IOL was counted after the central IOL area (0.04 mm2) was photographed with an inverted light microscope. Cell morphology was examined by scanning electron microscopy (SEM). More platelets and granulocytes were attached to the IM-PMMA and silicone IOLs than to the HSM-PMMA and polyHEMA IOLs (P < .05). RAW 264.7 and L929 cells grew on PMMA-based and silicone IOLs, whereas HSM-PMMA and polyHEMA IOLs did not support an abundant growth of these cells. Granulocytes were incubated with the IOLs in the presence of Luminol and the generation of chemiluminescence was measured. Poly(methyl methacrylate)-based IOLs caused granulocytes to release significant amounts of oxygen radicals, while the polyHEMA IOL was almost inactive in stimulating granulocytes. Silicone and HSM-PMMA IOLs showed an intermediate level of stimulating activity. The light intensity reached a peak within 14 minutes with the IM-PMMA IOL, and in about 18 minutes with the other IOLs. Our results suggest that IOL hydrophilicity prevents attachment of cells and that a hydrophilic, soft surface can discourage granulocyte stimulation.
引用
收藏
页码:240 / 246
页数:7
相关论文
共 12 条
[1]  
Kappelhof JP, Pameyer JH, De Jong PTVM, Et al., The proteinaceous coating and cytology of implant lenses in rabbits, Am J Ophthalmol, 102, pp. 750-758, (1986)
[2]  
Puck A, Tso MOM, Yue B, Cellular deposits on intraocular lenses, Acta Ophthalmol Suppl, 170, pp. 54-60, (1985)
[3]  
Wolter JR, Cytopathology of intraocular lens implantation, Ophthalmology, 92, pp. 135-142, (1985)
[4]  
Uenoyama K, Matoba M, Kanagawa R, Et al., Experimental intraocular lens implantation in the rabbit eye and in the mouse peritoneal space. Part I: Cellular components observed on the implanted lens surface, J Cataract Refract Surg, 14, pp. 187-191, (1988)
[5]  
Uenoyama K, Matoba M, Kanagawa R, Et al., Experimental intraocular lens implantation in the rabbit eye and in the mouse peritoneal space. Part III: Giant cell formation on the implanted lens surface, J Cataract Refract Surg, 14, pp. 197-201, (1988)
[6]  
Tuberville AW, Galin MA, Perez HD, Et al., Complement activation by nylon- and polypropylene-looped prosthetic intraocular lenses, Invest Ophthalmol Vis Sci, 22, pp. 727-733, (1982)
[7]  
Dahinden CA, Fehr J, Hugh TE, Role of cell surface contact in the kinetics of superoxide production by granulocytes, J Clin Invest, 72, pp. 113-121, (1983)
[8]  
Apple DJ, Mamalis N, Loftfield K, Et al., Complications of intraocular lenses. A historical and histopathological review, Surv Ophthalmol, 29, pp. 1-54, (1984)
[9]  
Ohara K, Biomicroscopy of surface deposits resembling foreign-body giant cells on implanted intraocular lenses, Am J Ophthalmol, 99, pp. 304-311, (1985)
[10]  
Larsson R, Rosengren A, Olsson P, Determination of platelet adhesion to polyethylene and heparinized surfaces with the aid of bioluminescence and 5 'chromium labelled platelets, Thromb Res, 11, pp. 517-530, (1977)