COMPARATIVE CRANIAL CT ENHANCEMENT IN A PRIMATE MODEL OF CEREBRAL INFARCTION

被引:13
作者
DRAYER, BP
DUJOVNY, M
WOLFSON, SK
BOEHNKE, M
COOK, EE
ROSENBAUM, AE
机构
[1] UNIV PITTSBURGH,SCH MED,DEPT RADIOL,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,SCH MED,DEPT NEUROL,PITTSBURGH,PA 15213
[3] UNIV PITTSBURGH,SCH MED,DEPT NEUROSURG,PITTSBURGH,PA 15213
[4] MONTEFIORE HOSP,DEPT RADIOL,PITTSBURGH,PA 15213
[5] MONTEFIORE HOSP,SURG RES LAB,PITTSBURGH,PA 15213
关键词
D O I
10.1002/ana.410050108
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The value of various enhancement techniques as opposed to nonenhanced CT scanning was compared in 15 baboons with cerebral infarction secondary to embolization of the left middle cerebral artery. The most prominent CT findings in infarction included an area of low absorption in the opercula–basal ganglia–centrum semiovale region and generalized lateral ventricular enlargement. Intravenous enhancement of the low‐density region occurred in 25% of the animals and often obscured the preenhancement abnormality. However, a rapid bolus injection of contrast material followed by immediate consecutive CT scans (computed angiotomography) permitted prominent visualization of early‐shunting veins. Delayed scanning following intrathecal enhancement better defined small infarctions that did not exhibit the usual cerebral blush. The CT imaging of inhaled xenon provides a new technique for evaluating subtle abnormalities in cerebral perfusion, even when the routine CT scan shows no abnormality. Copyright © 1979 American Neurological Association
引用
收藏
页码:48 / 58
页数:11
相关论文
共 14 条
[1]  
BAKER HL, 1974, MAYO CLIN PROC, V49, P17
[2]   CEREBRAL INFARCTION DIAGNOSIS BY COMPUTERIZED TOMOGRAPHY - ANALYSIS AND EVALUATION OF FINDINGS [J].
DAVIS, KR ;
TAVERAS, JM ;
NEW, PFJ ;
SCHNUR, JA ;
ROBERSON, GH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1975, 124 (04) :643-660
[3]  
Drayer B P, 1977, Acta Radiol Suppl, V355, P280
[4]   METRIZAMIDE COMPUTED TOMOGRAPHY CISTERNOGRAPHY - PEDIATRIC APPLICATIONS [J].
DRAYER, BP ;
ROSENBAUM, AE ;
REIGEL, DB ;
BANK, WO ;
DEEB, ZL .
RADIOLOGY, 1977, 124 (02) :349-357
[5]   CAPACITY FOR COMPUTED TOMOGRAPHY DIAGNOSIS OF CEREBRAL INFARCTION - EXPERIMENTAL-STUDY IN NONHUMAN PRIMATE [J].
DRAYER, BP ;
DUJOVNY, M ;
BOEHNKE, M ;
WOLFSON, SK ;
BARRIONUEVO, PJ ;
COOK, EE ;
ROSENBAUM, AE .
RADIOLOGY, 1977, 125 (02) :393-402
[6]   XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW [J].
DRAYER, BP ;
WOLFSON, SK ;
REINMUTH, OM ;
DUJOVNY, M ;
BOEHNKE, M ;
COOK, EE .
STROKE, 1978, 9 (02) :123-130
[7]   CEREBROSPINAL-FLUID IMAGING USING SERIAL METRIZAMIDE CT CISTERNOGRAPHY [J].
DRAYER, BP ;
ROSENBAUM, AE ;
HIGMAN, HB .
NEURORADIOLOGY, 1977, 13 (01) :7-17
[8]   EXTRAVASCULAR COMPONENT OF CONTRAST ENHANCEMENT IN CRANIAL COMPUTED TOMOGRAPHY .2. CONTRAST ENHANCEMENT AND BLOOD-TISSUE BARRIER [J].
GADO, MH ;
PHELPS, ME ;
COLEMAN, RE .
RADIOLOGY, 1975, 117 (03) :595-597
[9]   APPROACH TO CONTRAST ENHANCEMENT IN COMPUTED TOMOGRAPHY OF BRAIN [J].
KRAMER, RA ;
JANETOS, GP ;
PERLSTEIN, G .
RADIOLOGY, 1975, 116 (03) :641-647
[10]   CLASSIFICATION OF EXPERIMENTAL MODELS OF BRAIN ISCHEMIA [J].
MOLINARI, GF ;
LAURENT, JP .
STROKE, 1976, 7 (01) :14-17