摘要
Phased-array imaging, including complete dynamic focus, is explored for imaging using a circular aperture. Based on the constraints of catheter-based systems, an efficient synthetic aperture method has been developed for imaging using a single wire connection between the imaging array and external electronics. The method employs a highly sampled array with an element pitch small compared to an acoustic wavelength. On any given firing of the array, however, a large number of channels are electrically connected on both transmission and reception. From firing to firing, one element is dropped and one new element is included, in analogy to a classic linear array system. Using an optimal filtering approach for synthetic aperture reconstruction, a dynamically focused image exhibiting diffraction limited resolution is produced. The results of detailed simulations are presented demonstrating the capabilities of the method. In addition, the prospects for real-time implementation of the reconstruction are discussed.
引用
收藏
页码:366 / 380
页数:15
相关论文
共 27 条
  • [1] Bom N, 1989, Int J Card Imaging, V4, P79, DOI 10.1007/BF01745137
  • [2] ULTRASONIC INTRACARDIAC SCANNER
    BOM, N
    LANCEE, CT
    VANEGMON.FC
    [J]. ULTRASONICS, 1972, 10 (02) : 72 - &
  • [3] CORL PD, 1980, ACOUST IMAGING, V8, P39
  • [4] DAFT CMW, 1990, 1990 P IEEE ULTR S, P775
  • [5] SUDDEN CARDIAC DEATH
    EISENBERG, MS
    BERGNER, L
    HALLSTROM, AP
    CUMMINS, RO
    [J]. SCIENTIFIC AMERICAN, 1986, 254 (05) : 37 - &
  • [6] TEXTURAL VARIATIONS IN B-MODE ULTRASONOGRAPHY - A STOCHASTIC-MODEL
    FLAX, SW
    GLOVER, GH
    PELC, NJ
    [J]. ULTRASONIC IMAGING, 1981, 3 (03) : 235 - 257
  • [7] CHARACTERIZATION OF LEAD ZIRCONATE TITANATE CERAMICS FOR USE IN MINIATURE HIGH-FREQUENCY (20-80 MHZ) TRANSDUCERS
    FOSTER, FS
    RYAN, LK
    TURNBULL, DH
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) : 446 - 453
  • [8] ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY
    GUSSENHOVEN, EJ
    ESSED, CE
    LANCEE, CT
    MASTIK, F
    FRIETMAN, P
    VANEGMOND, FC
    REIBER, J
    BOSCH, H
    VANURK, H
    ROELANDT, J
    BOM, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 947 - 952
  • [9] EFFICACY AND SAFETY OF CORONARY BALLOON ANGIOPLASTY AND DIRECTIONAL ATHERECTOMY
    HILLIS, LD
    [J]. CIRCULATION, 1990, 82 (01) : 305 - 307
  • [10] HODGSON J, 1989, INT J CARDIAC IMAGIN, V4, P1587