ON THE APPLICATION OF ULTRA-FAST RARE EXPERIMENTS

被引:141
作者
NORRIS, DG
BORNERT, P
REESE, T
LEIBFRITZ, D
机构
[1] Fachbereich Chemie, Universität Bremen, Bremen
[2] Philips Gmbh, Forschungslaboratorium, Hamburg, D 2000, Vogt-Kölln Strasse
关键词
D O I
10.1002/mrm.1910270114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ultra‐fast application of the RARE experiment is described in detail, with special emphasis on its multifarious applications with preparation experiments that produce transverse magnetization. The factors affecting the temporal evolution of the magnetization during the experiment are described, and the implications for the slice profile when using a Gaussian refocusing pulse are experimentally examined. The choice of phase‐encoding scheme for use with preparation experiments is discussed, as is the use of various phase‐encoding schemes to reduce line broadening in the phase‐encoding direction if a number of averages are acquired. An explanation for the decomposition of the echo are into two components if the read gradient is imbalanced is given, and the experimental conditions necessary for the coherent addition of these two echo groups are described. An alternative sequence that removes one of these groups from the acquisition window is proposed. The sensitivity of the sequence to flow and motion is investigated, and the drastic loss of signal in this situation explained. The in vivo and in vitro application of preparation experiments leading to the accurate measurement of T1, T2, diffusion constant, and magnetization transfer characteristics is presented. The implementation of zoom‐imaging using spin‐ and stimulated‐echo preparation is described, and 3D in vivo spin‐echo zoom images are presented. Simple phantom experiments demonstrating the feasibility of chemical‐shift selective and spectroscopic imaging are also given. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:142 / 164
页数:23
相关论文
共 48 条
[1]  
BORNERT P, 1991, 10TH P ANN M SOC MAG, P306
[2]   INVIVO NUCLEAR MAGNETIC-RESONANCE CHEMICAL-SHIFT IMAGING BY SELECTIVE IRRADIATION [J].
BOTTOMLEY, PA ;
FOSTER, TH ;
LEUE, WM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (21) :6856-6860
[3]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[4]  
DEIMLING M, 1986, 5TH SMRM MONTREAL, P926
[5]   SELF-REFOCUSING 270-DEGREES GAUSSIAN PULSES FOR SLICE SELECTION WITHOUT GRADIENT REVERSAL IN MAGNETIC-RESONANCE IMAGING [J].
EMSLEY, L ;
BODENHAUSEN, G .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (02) :273-281
[6]   QUANTITATIVE H-1 MAGNETIZATION TRANSFER IMAGING INVIVO [J].
ENG, J ;
CECKLER, TL ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :304-314
[7]  
Foster M.P., 1987, PRACTICAL NMR IMAGIN, VB
[8]  
FRAHM J, 1986, 5TH P ANN M SOC MAGN, P158
[9]  
GRANOT J, 1986, 5TH P ANN M SOC MAGN, P973
[10]   INVERSION RECOVERY SNAPSHOT FLASH MR IMAGING [J].
HAASE, A ;
MATTHAEI, D ;
BARTKOWSKI, R ;
DUHMKE, E ;
LEIBFRITZ, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) :1036-1040