METERED-DOSE INHALERS AND NEBULIZERS IN THE ACUTE SETTING

被引:20
作者
KISCH, GL
PALOUCEK, FP
机构
[1] UNIV ILLINOIS,COLL PHARM,DEPT PHARM PRACTICE,ROOM 244,M-C 886,833 S WOOD ST,CHICAGO,IL 60612
[2] BUTLER UNIV,PHARM PRACTICE,INDIANAPOLIS,IN 46208
[3] METHODIST HOSP INDIANA,INDIANAPOLIS,IN 46202
关键词
D O I
10.1177/106002809202600116
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: This article evaluates the current literature comparing beta-adrenergic agonists administered via metered-dose inhalers (MDIs) with nebulizer devices in adult and pediatric patients. These studies focus on the acute treatment of asthma or chronic objective pulmonary disease in the emergency department and other acute care settings. DATA SOURCES: English-language journal articles published between 1980 and 1991. STUDY SELECTION: Eight studies that compared beta-adrenergic agonists administered via an MDI or an MDI with a spacing device versus a nebulizer were identified. All of the studies were either poorly designed or had few subjects. By consensus of the authors, all were included in the review. DATA EXTRACTION: Studies were assessed according to methodologic strength (e.g., prospective, comparative). DATA SYNTHESIS: Five studies found no differences between administration methods, one study found metered-dose inhalation to be superior, and another found nebulization to be superior based on observed improvements in pulmonary function tests. There were no significant differences in adverse-reaction rates. When surveyed, subjects preferred MDIs to nebulizers. There were marked variations in doses administered within and between studies. There was no consideration given to doses potentially delivered to the lungs. CONCLUSIONS: There is no significant difference between nebulizers and MDIs plus a spacer with regard to the administration of beta-agonists in the treatment of acute asthma. There are insufficient data to conclusively support the role of spacers in this setting. The choice of a specific delivery method at this time must be determined on an individual basis, taking into account the issues of cost, timeliness of administration, and personnel availability.
引用
收藏
页码:92 / 95
页数:4
相关论文
共 10 条
[1]  
BEASLEY CRW, 1985, NEW ZEAL MED J, V98, P854
[2]   NEBUHALER VERSUS NEBULIZER IN CHILDREN WITH ACUTE ASTHMA [J].
FREELANDER, M ;
VANASPEREN, PP .
BRITISH MEDICAL JOURNAL, 1984, 288 (6434) :1873-1874
[3]  
FUGLSANG G, 1986, EUR J RESPIR DIS, V69, P109
[4]   TERBUTALINE AEROSOL GIVEN THROUGH PEAR SPACER IN ACUTE SEVERE ASTHMA [J].
MORGAN, MDL ;
SINGH, BV ;
FRAME, MH ;
WILLIAMS, SJ .
BRITISH MEDICAL JOURNAL, 1982, 285 (6345) :849-850
[5]   COMPARATIVE EFFICACY OF TERBUTALINE ADMINISTERED BY NEBUHALER AND BY NEBULIZER IN YOUNG-CHILDREN WITH ACUTE ASTHMA [J].
PENDERGAST, J ;
HOPKINS, J ;
TIMMS, B ;
VANASPEREN, PP .
MEDICAL JOURNAL OF AUSTRALIA, 1989, 151 (07) :406-408
[6]   AEROSOLIZED METAPROTERENOL IN THE TREATMENT OF ASTHMATICS WITH SEVERE AIR-FLOW OBSTRUCTION - COMPARISON OF 2 DELIVERY METHODS [J].
SALZMAN, GA ;
STEELE, MT ;
PRIBBLE, JP ;
ELENBAAS, RM ;
PYSZCZYNSKI, DR .
CHEST, 1989, 95 (05) :1017-1020
[7]   AEROSOL BRONCHODILATOR DELIVERY METHODS - RELATIVE IMPACT ON PULMONARY-FUNCTION AND COST OF RESPIRATORY CARE [J].
SUMMER, W ;
ELSTON, R ;
THARPE, L ;
NELSON, S ;
HAPONIK, EF .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (03) :618-623
[8]  
TARALA RA, 1980, BRIT J CLIN PHARMACO, V10, P393
[9]   EQUIVALENCE OF CONTINUOUS-FLOW NEBULIZER AND METERED-DOSE INHALER WITH RESERVOIR BAG FOR TREATMENT OF ACUTE AIR-FLOW OBSTRUCTION [J].
TURNER, JR ;
CORKERY, KJ ;
ECKMAN, D ;
GELB, AM ;
LIPAVSKY, A ;
SHEPPARD, D .
CHEST, 1988, 93 (03) :476-481
[10]  
WHELAN AM, 1991, DICP ANN PHARMAC, V25, P638