IMMUNOASSAYS FOR MEASUREMENT OF CHROMOGRANIN-A AND PANCREASTATIN-LIKE IMMUNOREACTIVITY IN HUMANS - CORRESPONDENCE IN PATIENTS WITH NEUROENDOCRINE NEOPLASIA

被引:45
作者
SYVERSEN, U
JACOBSEN, MB
OCONNOR, DT
RONNING, K
WALDUM, HL
机构
[1] UNIV OSLO,RIKSHOSP,DEPT MED,N-0027 OSLO,NORWAY
[2] UNIV CALIF SAN DIEGO,DEPT MED,SAN DIEGO,CA 92103
[3] UNIV CALIF SAN DIEGO,CTR MOLEC GENET,SAN DIEGO,CA 92161
[4] VET AFFAIRS MED CTR,SAN DIEGO,CA 92161
关键词
D O I
10.1016/0143-4179(94)90131-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chromogranin A (CgA) is a useful marker of neuroendocrine tumors in humans. Here we describe and compare two immunoassay methods for determination of CgA, a radioimmunoassay (RIA) and an enzyme linked immunoassay (ELISA). The detection limit of the ELISA was lower than that of the RIA method (2 ng/ml versus 10 ng/ml, respectively), though the CgA RIA method covered a wider range than the CgA ELISA (10-920 ng/ml versus 2-500 ng/ml, respectively). There was no cross-reactivity with synthetic human and porcine pancreastatin (PST) in the two assays. There was a significant positive correlation between levels of CgA in sera from patients with carcinoid disease, measured by the two methods (r = 0.9, p < 0.0001), and the values were in the same range. Similarly, serum CgA levels in normal controls were also in the same range when assayed by the two methods. A commercially available porcine PST RIA method was evaluated, especially with respect to the influence of Sep-Pak extraction of serum on the levels of pancreastatin-like immunoreactivity (PST-LI). Ten sera from carcinoid patients were treated with Sep-Pak extraction, and levels of PST-LI were determined in non-extracted and extracted sera. There was a significant positive correlation between the concentrations of PST-LI measured in extracted and non-extracted carcinoid sera (r = 0.9, p < 0.002), and the levels were in the same range. There was also a significant positive correlation between levels of CgA and PST-LI in 49 carcinoid sera (r = 0.8, p< 0.0001). In the PST RIA there was a minimal cross-reactivity with human CgA (0.08%). In conclusion, we have found that the two immunoassays for measurement of CgA are sensitive and reproducible, and give similar results. Extraction of serum previous to assaying PST-LI seems not to be necessary.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 27 条
[1]   PANCREASTATIN INHIBITS INSULIN-SECRETION AND STIMULATES GLUCAGON-SECRETION IN MICE [J].
AHREN, B ;
LINDSKOG, S ;
TATEMOTO, K ;
EFENDIC, S .
DIABETES, 1988, 37 (03) :281-285
[2]   PEROXIDASE LABELLED ANTIBODY AND FAB CONJUGATES WITH ENHANCED INTRACELLULAR PENETRATION [J].
AVRAMEAS, S ;
TERNYNCK, T .
IMMUNOCHEMISTRY, 1971, 8 (12) :1175-&
[3]  
BENDER H, 1992, CLIN CHEM, V38, P2267
[4]  
COHN DV, 1990, MOL CELLULAR REGULAT, P51
[5]  
DILLEN L, 1989, CLIN CHEM, V35, P1934
[6]   BOVINE PARATHYROID-GLANDS SECRETE A 26-KDA N-TERMINAL FRAGMENT OF CHROMOGRANIN-A WHICH INHIBITS PARATHYROID CELL SECRETION [J].
DREES, BM ;
ROUSE, J ;
JOHNSON, J ;
HAMILTON, JW .
ENDOCRINOLOGY, 1991, 129 (06) :3381-3387
[7]   PEPTIDE FUNCTION - IS CHROMOGRANIN A PROHORMONE [J].
EIDEN, LE .
NATURE, 1987, 325 (6102) :301-301
[8]   A POLYCLONAL ANTISERUM AGAINST CHROMOGRANIN-A AND CHROMOGRANIN-B - A NEW SENSITIVE MARKER FOR NEUROENDOCRINE TUMORS [J].
ERIKSSON, B ;
ARNBERG, H ;
OBERG, K ;
HELLMAN, U ;
LUNDQVIST, G ;
WERNSTEDT, C ;
WILANDER, E .
ACTA ENDOCRINOLOGICA, 1990, 122 (02) :145-155
[9]   IMMUNOLOGICAL CHARACTERIZATION OF SECRETORY PROTEINS OF CHROMAFFIN GRANULES - CHROMOGRANINS-A, CHROMOGRANINS-B, AND ENKEPHALIN-CONTAINING PEPTIDES [J].
FISCHERCOLBRIE, R ;
FRISCHENSCHLAGER, I .
JOURNAL OF NEUROCHEMISTRY, 1985, 44 (06) :1854-1861
[10]   ISOLATION AND CHARACTERIZATION OF CHROMOGRANIN-A, CHROMOGRANIN-B, AND CHROMOGRANIN-C FROM BOVINE CHROMAFFIN GRANULES AND A RAT PHEOCHROMOCYTOMA [J].
FISCHERCOLBRIE, R ;
SCHOBER, M .
JOURNAL OF NEUROCHEMISTRY, 1987, 48 (01) :262-270