ENHANCEMENT OF FIBRINOLYSIS INVITRO BY ULTRASOUND

被引:195
作者
FRANCIS, CW
ONUNDARSON, PT
CARSTENSEN, EL
BLINC, A
MELTZER, RS
SCHWARZ, K
MARDER, VJ
机构
[1] UNIV ROCHESTER, DEPT MED, HEMATOL UNIT, ROCHESTER, NY 14642 USA
[2] UNIV ROCHESTER, DEPT MED, CARDIOL UNIT, ROCHESTER, NY 14642 USA
[3] UNIV ROCHESTER, DEPT ELECT ENGN, ROCHESTER, NY 14642 USA
[4] UNIV ROCHESTER, ROCHESTER CTR BIOMED ULTRASOUND, ROCHESTER, NY 14642 USA
关键词
FIBRINOLYTIC THERAPY; FIBRINOLYSIS; ULTRASOUND; FIBRIN; FIBRINOGEN; TISSUE PLASMINOGEN ACTIVATOR; UROKINASE-LIKE PLASMINOGEN ACTIVATOR;
D O I
10.1172/JCI116088
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The effect of ultrasound on the rate of fibrinolysis has been investigated using an in vitro system. Plasma or blood clots containing a trace label of I-125 fibrin were suspended in plasma containing plasminogen activator and intermittently exposed to continuous wave 1-MHz ultrasound at intensities up to 8 W/cm2. Plasma clot lysis at 1 h with 1 mug/ml recombinant tissue plasminogen activator (rt-PA) was 12.8+/-1.2% without ultrasound and was significantly (P = 0.0001) increased by exposure to ultrasound with greater lysis at 1 W/cm2 (18.0 +/- 1.4%), 2 W/cm2 (19.3 +/- 0.7%), 4 W/cm2 (22.8 +/- 1.8%), and 8 W/CM2 (58.7 +/- 7.1 %). Significant increases in lysis were also seen with urokinase at ultrasound intensities of 2 W/cm2 and above. Exposure of clots to ultrasound in the absence of plasminogen activator did not increase lysis. Ultrasound exposure resulted in a marked reduction in the rt-PA concentration required to achieve an equivalent degree of lysis to that seen without ultrasound. For example, 15% lysis occurred in 1 h at 1 mug/ml rt-PA without ultrasound or with 0.2 mug/ml with ultrasound, a fivefold reduction in concentration. Ultrasound at 1 W/cm2 and above also potentiated lysis of retracted whole blood clots mediated by rt-PA or urokinase. The maximum temperature increase of plasma clots exposed to 4 W/cm2 ultrasound was only 1.7-degrees-C, which could not explain the enhancement of fibrinolysis. Ultrasound exposure did not cause mechanical fragmentation of the clot into sedimentable fragments, nor did it alter the sizes of plasmic derivatives as demonstrated by SDS polyacrylamide gel electrophoresis. We conclude that ultrasound at 1 MHz potentiates enzymatic fibrinolysis by a nonthermal mechanism at energies that can potentially be applied and tolerated in vivo to accelerate therapeutic fibrinolysis.
引用
收藏
页码:2063 / 2068
页数:6
相关论文
共 42 条
  • [1] [Anonymous], 1987, Lancet, V2, P871
  • [2] [Anonymous], 1988, LANCET, V2, P349
  • [3] GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND
    APFEL, RE
    HOLLAND, CK
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) : 179 - 185
  • [4] DISSOLUTION OF PERIPHERAL ARTERIAL THROMBI BY ULTRASOUND
    ARIANI, M
    FISHBEIN, MC
    CHAE, JS
    SADEGHI, H
    MICHAEL, TAD
    DUBIN, SB
    SIEGEL, RJ
    [J]. CIRCULATION, 1991, 84 (04) : 1680 - 1688
  • [5] BLINC A, 1991, THROMB HAEMOSTASIS, V65, P549
  • [6] FIBRIN HAS LARGER PORES WHEN FORMED IN THE PRESENCE OF ERYTHROCYTES
    CARR, ME
    HARDIN, CL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (05): : H1069 - H1073
  • [7] CHAMBERLAIN DA, 1990, LANCET, V335, P427
  • [8] PLATELET-AGGREGATION INDUCED INVITRO BY THERAPEUTIC ULTRASOUND
    CHATER, BV
    WILLIAMS, AR
    [J]. THROMBOSIS AND HAEMOSTASIS, 1977, 38 (03) : 640 - 651
  • [9] THROMBOLYSIS IN MYOCARDIAL-INFARCTION (TIMI) TRIAL, PHASE-I - A COMPARISON BETWEEN INTRAVENOUS TISSUE PLASMINOGEN-ACTIVATOR AND INTRAVENOUS STREPTOKINASE - CLINICAL FINDINGS THROUGH HOSPITAL DISCHARGE
    CHESEBRO, JH
    KNATTERUD, G
    ROBERTS, R
    BORER, J
    COHEN, LS
    DALEN, J
    DODGE, HT
    FRANCIS, CK
    HILLIS, D
    LUDBROOK, P
    MARKIS, JE
    MUELLER, H
    PASSAMANI, ER
    POWERS, ER
    RAO, AK
    ROBERTSON, T
    ROSS, A
    RYAN, TJ
    SOBEL, BE
    WILLERSON, J
    WILLIAMS, DO
    ZARET, BL
    BRAUNWALD, E
    [J]. CIRCULATION, 1987, 76 (01) : 142 - 154
  • [10] ABILITY OF HIGH-INTENSITY ULTRASOUND TO ABLATE HUMAN ATHEROSCLEROTIC PLAQUES AND MINIMIZE DEBRIS SIZE
    ERNST, A
    SCHENK, EA
    GRACEWSKI, SM
    WOODLOCK, TJ
    MURANT, FG
    ALLIGER, H
    MELTZER, RS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (02) : 242 - 246