MODEL-BASED ESTIMATION OF VASCULAR PARAMETERS - EVALUATION OF ROBUSTNESS AND SUITABILITY OF MODELS

被引:1
作者
ANGELSEN, BAJ
AAKHUS, S
RABBEN, SI
TORP, HG
机构
[1] Department of Medicine, Section of Cardiology, University of Trondheim, Center for Medical Technology, Trondheim
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 1994年 / 11卷 / 04期
关键词
AORTIC ROOT PRESSURE; VASCULAR MODEL;
D O I
10.1111/j.1540-8175.1994.tb01383.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular performance depends not only on myocardial state, but also on the properties of the systemic arterial tree. These properties can be assessed from recordings of aortic root pressure and flow by the use of appropriate vascular models. Noninvasive estimates of aortic root pressure and flow can be obtained by the combined use of calibrated external subclavian artery pulse tracing and Doppler echocardiography. With recent advances in computer technology, estimation of model parameters are thus accessible in the clinical setting. We discuss the suitability of different parametric vascular models together with methods for adapting these models to the measured aortic root pressure. We compared the results obtained with simple vascular models (three-component modified Windkessel models) with those of five-component models. The simpler models gave less accurate approximation of the measured pressure waveform, but for a representative set of aortic root pressure and flow data, the simpler models provided adequate estimates of the peripheral arterial resistance, the total arterial compliance, and the proximal aortic area compliance. Furthermore, the simpler models are robust for measurement noise with simple estimation algorithms. Distal arterial pressure and flow waveforms are more oscillatory, and for these the five-component model has more robust estimation schemes with more accurate estimated parameters. Hence, we conclude that for clinical noninvasive assessment of aortic vascular properties, the simpler three-component models provide adequate information. For assessment of the peripheral arteries with large oscillations in the flow, the three-component models can give more than 10% error in the compliance estimate and more complex models can be appropriate.
引用
收藏
页码:409 / 423
页数:15
相关论文
共 37 条
[1]  
Laskey WK, Kussmaul WG, Martin JL, Et al., Characteristics of vascular hydraulic load in patients with heart failure, Circulation, 72, pp. 61-71, (1985)
[2]  
Devereux RB, Toward a more complete understanding of left ventricular afterload, JACC, 17, pp. 122-124, (1991)
[3]  
Milnor WR, Arterial impedance as ventricular afterload, Circ Res, 36, pp. 565-570, (1975)
[4]  
Burkhoff D, Alexander J, Schipke J, Assessment of windkessel as a model of aortic input impedance, Am J Physiol, 255, pp. 742-753, (1988)
[5]  
Westerhof N, Elzinga G, Sipkema P, An artificial arterial system for pumping hearts, J Appl Physiol, 31, pp. 776-781, (1971)
[6]  
Laskey WK, Parker G, Ferrari VA, Et al., Estimation of total systemic arterial compliance in humans, J Appl Physiol, 69, pp. 112-119, (1990)
[7]  
Slordahl SS, Piene H, Solbakken JE, Et al., pp. 293-299, (1990)
[8]  
Simon AC, Safar ME, Levenson JA, Et al., An evaluation of large arteries compliance in man, Am J Physiol, 237, (1979)
[9]  
Skjaerpe T, Hegrenaes L, Ihlen H, Cardiac output, Doppler Ultrasound in Cardiology, pp. 306-320, (1985)
[10]  
Spencer KT, Lang RM, Neumann A, Et al., Doppler and electromagnetic comparisons of instantaneous aortic flow characteristics in primates, Circ Res, 68, pp. 1369-1377, (1991)