摘要
A method for assessing the extent and uniformity of film-coat application on to tablets by the determination of titanium is reported. The method is utilised to determine the ideal charge of tablets in a 24" Accela-Cota for the application of a water insoluble film-coat which is intended to be rate controlling. The results are compared with those obtained using conventional methods of process optimisation ie dissolution testing.