APPLICATION OF PASSIVE SAMPLERS TO THE MONITORING OF LOW CONCENTRATION ORGANIC VAPORS IN INDOOR AND AMBIENT AIR - A REVIEW

被引:33
作者
CAO, XL [1 ]
HEWITT, CN [1 ]
机构
[1] UNIV LANCASTER,INST ENVIRONM & BIOL SCI,LANCASTER LA1 4YQ,ENGLAND
关键词
PASSIVE SAMPLERS; LOW CONCENTRATION; ORGANIC VAPORS; INDOOR AIR; AMBIENT AIR;
D O I
10.1080/09593339109385104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a review of the recent application of passive samplers for the sampling of low concentration organic vapours in indoor and ambient air. Theoretical equations describing the operation of various types of passive samplers are summarized. The problems associated with the application of passive samplers for the sampling of organic vapours in indoor and ambient air, and the factors affecting the performance of passive samplers are discussed. It is suggested the effective cross-sectional area be employed in calculating the diffusion uptake rate according to DA/L instead of the total cross-sectional area. It is further suggested that suitable passive samplers with a higher uptake rate should be designed (e.g. by reducing the diffusion length), and a new and simple validation procedure should be developed for their application in indoor and ambient air environments.
引用
收藏
页码:1055 / 1062
页数:8
相关论文
共 48 条
  • [1] BAILEY A, 1977, Annals of Occupational Hygiene, V20, P345, DOI 10.1093/annhyg/20.4.345
  • [2] BAILEY A, 1981, TRACE ORGANIC SAMPLE, V10, P43
  • [3] A PERSONAL AMMONIA MONITOR UTILIZING PERMEATION SAMPLING
    BENEDICT, AF
    REISZNER, KD
    WEST, PW
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1983, 44 (01): : 66 - 70
  • [4] A THERMALLY-DESORBABLE PASSIVE DOSIMETER FOR PERSONAL MONITORING FOR ACRYLONITRILE
    BENSON, GB
    BOYCE, GE
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1981, 24 (01) : 55 - &
  • [5] INDUSTRIAL-HYGIENE MEASUREMENTS FOR ORGANIC POLLUTANTS (ACRYLONITRILE) USING PASSIVE DOSIMETERS AND AUTOMATED THERMAL-DESORPTION
    BENSON, GB
    BOYCE, GE
    HAILE, DM
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1981, 24 (04) : 367 - 373
  • [6] A GRAPHITIZED CARBON-BLACK DIFFUSIVE SAMPLER FOR THE MONITORING OF ORGANIC VAPORS IN THE ENVIRONMENT
    BERTONI, G
    PERRINO, C
    LIBERTI, A
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1982, 15 (12): : 1039 - 1050
  • [7] CRITICAL PARAMETERS FOR THE ADSORPTION OF GASEOUS-POLLUTANTS ON PASSIVE SAMPLERS MADE OF LOW SPECIFIC AREA ADSORBENTS
    BERTONI, G
    PERRINO, C
    FRATARCANGELI, R
    LIBERTI, A
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (04): : 429 - 438
  • [8] EVALUATION TESTS AND APPLICATIONS OF A DOUBLE-LAYER TUBE-TYPE PASSIVE SAMPLER
    BERTONI, G
    CANEPARI, S
    ROTATORI, M
    FRATARCANGELI, R
    LIBERTI, A
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 522 : 285 - 294
  • [9] BROWN RH, 1984, AM IND HYG ASSOC J, V45, P67
  • [10] THE DEVELOPMENT OF AN IMPROVED DIFFUSIVE SAMPLER
    BROWN, RH
    CHARLTON, J
    SAUNDERS, KJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1981, 42 (12): : 865 - 869