COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF BO-2727, A NEW CARBAPENEM ANTIBIOTIC, IN HUMAN PLASMA AND URINE BY DIRECT-INJECTION

被引:10
作者
TAKANO, T [1 ]
KAGAMI, Y [1 ]
KUWABARA, Y [1 ]
HATA, S [1 ]
机构
[1] BANYU PHARMACEUT CO,DEV RES LABS,DRUG METAB,SAITAMA 36002,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 656卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00128-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A column-switching high-performance liquid chromatographic method has been developed for the simple and sensitive analysis of BO-2727 (I) in human plasma and urine. Plasma samples were diluted with an equal volume of a stabilizer, and the mixture was directly injected onto the HPLC system. The analyte was enriched in a pre-treatment column, while endogenous components were eluted to waste. The analyte was then backflushed onto an analytical column and quantified with ultraviolet detection. Urinary concentrations were determined in a similar way except that the enriched analyte was eluted in the foreflush mode to a cation-exchange column used for chromatographic separation. The standard curves for the drug were linear in the range of 0.05-50 mu g/ml in plasma and 0.5-100 mu g/ml in urine. The limits of quantification for plasma and urine were found to be 0.05 mu g/ml and 0.5 mu g/ml, respectively. This method was used to support Phase I clinical pharmacokinetic studies.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 13 条
[1]   PROCEDURES FOR DIRECT INJECTIONS OF UNTREATED BLOOD-PLASMA INTO LIQUID-CHROMATOGRAPHIC COLUMNS WITH EMPHASIS ON A PRE-COLUMN VENTING TECHNIQUE [J].
ARVIDSSON, T ;
WAHLUND, KG ;
DAOUD, N .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :213-226
[2]   THE PHARMACOKINETICS OF MEROPENEM IN VOLUNTEERS [J].
BAX, RP ;
BASTAIN, W ;
FEATHERSTONE, A ;
WILKINSON, DM ;
HUTCHISON, M ;
HAWORTH, SJ .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1989, 24 :311-320
[3]  
CAMPINSFALCO P, 1993, J CHROMATOGR, V619, P173
[4]   AUTOMATED-DETERMINATION OF AMOXYCILLIN IN BIOLOGICAL-FLUIDS BY COLUMN SWITCHING IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHIC SYSTEMS WITH POST-COLUMN DERIVATIZATION [J].
CARLQVIST, J ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :285-296
[5]   DETERMINATION OF AMIFLOXACIN AND 2 OF ITS PRINCIPAL METABOLITES IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING [J].
CRAWMER, BP ;
COOK, JA ;
BROWN, RR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (02) :407-417
[6]   AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SPIRAMYCIN BY DIRECT INJECTION OF PLASMA, USING COLUMN-SWITCHING FOR SAMPLE CLEANUP [J].
DOW, J ;
LEMAR, M ;
FRYDMAN, A ;
GAILLOT, J .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :275-283
[7]  
Hisaoka M., 1991, CHEMOTHERAPY, V39, P197
[8]  
NAKASHIMA M, IN PRESS J ANTIMICRO
[9]  
OKAMOTO O, 1993, 33RD INT C ANT AG CH, P284
[10]   MEASUREMENT OF RIFAMPICIN AND 25-DESACETYLRIFAMPICIN IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIRECT SAMPLE INJECTION [J].
OLDFIELD, S ;
BERG, JD ;
STILES, HJ ;
BUCKLEY, BM .
JOURNAL OF CHROMATOGRAPHY, 1986, 377 :423-429