T2-WEIGHTED BREATH-HOLD MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A 3-DIMENSIONAL STEADY-STATE FREE PRECESSION SEQUENCE IN 87 PATIENTS

被引:38
作者
TAUPITZ, M
SPEIDEL, A
HAMM, B
DEIMLING, M
REICHEL, M
BOCK, A
WOLF, KJ
机构
[1] FREE UNIV BERLIN,KLINIKUM BENJAMIN FRANKLIN,DEPT RADIOL,BERLIN,GERMANY
[2] SIEMENS MED ENGN GRP,ERLANGEN,GERMANY
关键词
LIVER NEOPLASMS; MR; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.194.2.7824724
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a fast three-dimensional (3D) sequence that permits the acquisition of 16 T2-weighted images within a 29-second breath hold for magnetic resonance (MR) imaging of the liver. MATERIALS AND METHODS: Eighty-seven patients with focal liver lesions were examined at 1.5 T by using a 3D reversed fast imaging with steady-state precession (PSIF) sequence at flip angles of 15 degrees, 30 degrees and 70 degrees and a T2-weighted spin-echo (SE) sequence. Quantitative and qualitative image analysis was performed, RESULTS: Contrast and signal difference-to-noise ratios were 56% and 33% (liver-spleen) and 76% and 68% (liver-tumor), respectively, with the 3D-PSIF sequence compared with the T2-weighted SE sequence. With 3D-PSIF, overall image quality was poorer than that of the T2-weighted SE sequence at flip angles of 15 degrees but was similar at 30 degrees and 70 degrees. At low flip angles (15 degrees and 30 degrees) all lesion types were hyperintense. At a flip angle of 70 degrees, it was predominantly cysts and hemangiomas that showed high signal intensity. With the 3D-PSIF sequence, intrahepatic vessels are void of signal and can be better distinguished from small liver lesions compared with the flow-compensated T2-weighted SE sequence. CONCLUSION: The fast 3D-PSIF sequence is a valuable addition to MR imaging of the liver.
引用
收藏
页码:439 / 446
页数:8
相关论文
共 24 条
[1]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[2]   FRODO PULSE SEQUENCES - A NEW MEANS OF ELIMINATING MOTION, FLOW, AND WRAPAROUND ARTIFACTS [J].
EDELMAN, RR ;
ATKINSON, DJ ;
SILVER, MS ;
LOAIZA, FL ;
WARREN, WS .
RADIOLOGY, 1988, 166 (01) :231-236
[3]   SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST [J].
EDELMAN, RR ;
WALLNER, B ;
SINGER, A ;
ATKINSON, DJ ;
SAINI, S .
RADIOLOGY, 1990, 177 (02) :515-521
[4]   RAPID MR IMAGING WITH SUSPENDED RESPIRATION - CLINICAL-APPLICATION IN THE LIVER [J].
EDELMAN, RR ;
HAHN, PF ;
BUXTON, R ;
WITTENBERG, J ;
FERRUCCI, JT ;
SAINI, S ;
BRADY, TJ .
RADIOLOGY, 1986, 161 (01) :125-131
[5]  
ELSTER AD, 1993, RADIOLOGY, V186, P1
[6]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[7]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[8]   DIFFERENTIATION BETWEEN HEMANGIOMAS AND METASTASES OF THE LIVER WITH ULTRAFAST MR IMAGING - PRELIMINARY-RESULTS WITH T2 CALCULATIONS [J].
GOLDBERG, MA ;
SAINI, S ;
HAHN, PF ;
EGGLIN, TK ;
MUELLER, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) :727-730
[10]   IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS [J].
HAACKE, EM ;
LENZ, GW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1251-1258