ELECTROCHEMISTRY AND DETECTION OF SOME ORGANIC AND BIOLOGICAL MOLECULES AT CONDUCTING POLY(3-METHYLTHIOPHENE) ELECTRODES

被引:71
作者
ATTA, NF [1 ]
GALAL, A [1 ]
KARAGOZLER, AE [1 ]
RUSSELL, GC [1 ]
ZIMMER, H [1 ]
MARK, HB [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,EDISON SENSOR TECHNOL CTR,CINCINNATI,OH 45221
关键词
ACETAMINOPHEN; ASCORBIC ACID; CATECHOL; CONDUCTING POLYMERS; DOPAMINE; ELECTROCATALYSIS; ELECTROLYTE; EPINEPHRINE; FLOW INJECTION ANALYSIS; HYDROQUINONE; MODIFIED; ELECTRODE; NADH; P-AMINOPHENOL; POLY(3-METHYLTHIOPHENE); VOLTAMMETRY;
D O I
10.1016/0956-5663(91)85020-W
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrodes modified by the electrodeposition of poly(3-methylthiophene) were used as chemical sensors for some organic and biological molecules of industrial and medicinal interest. The electrochemical behaviors of ferri/ferrocyanide, catechol, ascorbic acid, hydroquinone, dopamine epinephrine, acetaminophen, p-aminophenol and NADH were examined by cyclic voltammetry. The results showed that the proposed modified surface catalyzes the oxidation of these compounds. Differential pulse and square wave techniques were used for the analysis of binary mixture of ascorbic acid with catechol, NADH, dopamine and p-aminophenol. Voltammetric peak resolution was also demonstrated for a ternary mixture of ascorbic acid, catechol and p-aminophenol. Polymer coated electrode was also used in an amperometric detector for flow injection analysis of most of the aforementioned compounds. The responses of the polymer electrode were 4-10 times larger as compared to those of platinum. The modified electrode displayed excellent response stability for successive injections and detection limits were 10 ppb for catechol, dopamine, epinephrine, NADH and p-aminophenol, 1 ppb for acetaminophen and 100 ppb for ascorbic acid. Voltammetric peak positions were affected by the nature of the electrolyte and its pH. Also, film thickness were shown to be a factor affecting both the current magnitudes and oxidation peak potential of NADH.
引用
收藏
页码:333 / 341
页数:9
相关论文
共 16 条
  • [1] PULSE VOLTAMMETRY WITH MICROVOLTAMMETRIC ELECTRODES
    EWING, AG
    DAYTON, MA
    WIGHTMAN, RM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (12) : 1842 - 1847
  • [2] HILLMAN AR, 1987, ELECTROCHEMICAL SCI, V1, P241
  • [3] POLYPYRROLE ELECTRODE AS A DETECTOR FOR ELECTROINACTIVE ANIONS BY FLOW-INJECTION ANALYSIS
    IKARIYAMA, Y
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (08) : 1803 - 1806
  • [4] MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
  • [5] CHEMICALLY MODIFIED ELECTRODES - MOLECULAR DESIGN FOR ELECTROANALYSIS
    MURRAY, RW
    EWING, AG
    DURST, RA
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (05) : A379 - &
  • [6] CHEMICALLY MODIFIED ELECTRODES
    MURRAY, RW
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1980, 13 (05) : 135 - 141
  • [7] NADA FA, 1991, J CHEM SOC CHEM COMM, V19, P1347
  • [8] ION-EXCHANGE AND TRANSPORT OF NEUROTRANSMITTERS IN NAFION FILMS ON CONVENTIONAL AND MICROELECTRODE SURFACES
    NAGY, G
    GERHARDT, GA
    OKE, AF
    RICE, ME
    ADAMS, RN
    MOORE, RB
    SZENTIRMAY, MN
    MARTIN, CR
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2): : 85 - 94
  • [9] CHEMICALLY MODIFIED ELECTRODES - A GENERAL OVERVIEW
    REDEPENNING, JG
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (01) : 18 - 22
  • [10] RUSSELL GC, 1989, 1989 PITTSB C ATL