INFLUENCE OF PARTICLE MASS AND ENERGY ON DIAMETER OF TRACKS

被引:10
作者
LECERF, M
PETER, J
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1972年 / 104卷 / 01期
关键词
D O I
10.1016/0029-554X(72)90316-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Glass has been irradiated orthogonally with respect to its surface by **1**2C, **1**6O, **2**0Ne, **4**0Ar, Ni and **8**4Kr ions of energy per nucleon ranging up to 1. 1. MeV/amu. The diameter of the etched particle tracks was measured as a function of the mass and velocity of the particle. It increases with the mass and energy of the projectile. The increase with mass is greatest between O and Ar and much smaller for heavier particles. The projectile detection threshold appears to occur in the vicinity of oxygen. Particles of charge greater than or equal to 10 and energy greater than 6 MeV are detected with 100% efficiency.
引用
收藏
页码:189 / &
相关论文
共 12 条
[1]  
BARON E, 1971 P INT C HEAV IO
[2]  
BLOK HP, TO BE PUBLISHED
[3]  
CRANSHAW TE, 1952, PROGR NUCL PHYS, V2, P271
[4]   NUCLEAR-PARTICLE-TRACK IDENTIFICATION IN INORGANIC SOLIDS [J].
FLEISCHE.RL ;
PRICE, PB ;
WOODS, RT .
PHYSICAL REVIEW, 1969, 188 (02) :563-&
[5]   SOLID-STATE TRACK DETECTORS - APPLICATIONS TO NUCLEAR SCIENCE AND GEOPHYSICS [J].
FLEISCHER, RL ;
PRICE, PB ;
WALKER, RM .
ANNUAL REVIEW OF NUCLEAR SCIENCE, 1965, 15 :1-+
[6]  
FLEISCHER RL, 1964, PHYS REV, V131, pA144
[7]  
GOLDSTEIN C, 1960, THESIS U ORSAY
[8]   DIAMETER OF ETCHED FISSION FRAGMENT TRACKS IN SOLID STATE NUCLEAR TRACK DETECTORS AS A FUNCTION OF PARTICLE ENERGY [J].
HOPPNER, U ;
KONECNY, E ;
FIEDLER, G .
NUCLEAR INSTRUMENTS & METHODS, 1969, 74 (02) :285-&
[9]  
LEISCHNER E, 1966, 166 I ANG PHYS HEID
[10]   HIGH-ENERGY PHOTOFISSION OF HEAVY AND MEDIUM-HEAVY ELEMENTS [J].
METHASIRI, T ;