THEORETICAL ACCOUNT OF THE SENSITIZATION AND DE-SENSITIZATION IN QUARTZ

被引:13
作者
CHEN, R
FOGEL, G
KRISTIANPOLLER, N
机构
[1] School of Physics and Astronomy, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel-Aviv University, Tel-Aviv
关键词
D O I
10.1016/1350-4487(94)90052-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A model is presented which can explain previously published experimental results of sensitization and de-sensitization of the 460 nm emission in the 110 degrees C TL peak in synthetic quartz. The simple model presented includes one kind of recombination center and two kinds of trapping states, one directly related to the TL peak and the other which acts as a competitor. Once a set of parameters is chosen, the set of simultaneous differential equations is numerically solved for the three stages of the experiment, namely, excitation, relaxation and heating in each cycle. Following the experimental procedure, such repeated cycles are performed starting from either low or high initial sensitivity. For a given repeated ''test dose'', the sensitivity approaches the same equilibrium level, starting from either low or high values, both in the experiments and simulated results. This agreement between the experimental and numerical results adds credibility to the competing trap model of sensitization. As opposed to the conventional pre-dose effect of the 380 nm emission, the occurrence of the hole reservoir is not required for the model.
引用
收藏
页码:277 / 279
页数:3
相关论文
共 12 条
[1]  
AITKEN MJ, 1976, EDINBURGH S ARCHAEOM
[2]   PREDOSE AND INCLUSION DATING - A COMPARISON USING IRON-AGE AND EARLY MEDIEVAL POTTERY [J].
BAILIFF, IK .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1985, 10 (4-6) :771-777
[3]   THE STRONGLY SUPERLINEAR DOSE DEPENDENCE OF THERMO-LUMINESCENCE IN SYNTHETIC QUARTZ [J].
CHEN, R ;
YANG, XH ;
MCKEEVER, SWS .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1988, 21 (09) :1452-1457
[4]   SENSITIZATION OF THERMOLUMINESCENCE IN SYNTHETIC QUARTZ - HEAT-TREATMENT AND RADIATION EFFECTS [J].
CHEN, R ;
ABURAYYA, M ;
KRISTIANPOLLER, N .
JOURNAL OF LUMINESCENCE, 1991, 48-9 :833-837
[5]  
CHEN R, 1993, RADIAT PROT DOSIM, V47, P23
[6]  
CHEN R, 1979, PACT, V3, P325
[7]   QUARTZ AS A HEAT-RESISTANT DOSIMETER [J].
FLEMING, SJ ;
THOMPSON, J .
HEALTH PHYSICS, 1970, 18 (05) :567-+
[8]   DOSE DEPENDENCE OF THERMOLUMINESCENCE PEAKS [J].
KRISTIANPOLLER, N ;
CHEN, R ;
ISRAELI, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (07) :1063-1072
[9]   POINT-DEFECTS AND THE PREDOSE EFFECT IN NATURAL QUARTZ [J].
MCKEEVER, SWS ;
CHEN, CY ;
HALLIBURTON, LE .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1985, 10 (4-6) :489-495
[10]  
YANG XH, 1988, NUCL TRACKS RAD MEAS, V14, P75