ACCURACY OF BIOMETRICAL DATA OBTAINED FROM THE NIDEK EAS-1000

被引:29
作者
SAKAMOTO, Y
SASAKI, K
机构
[1] Department of Ophthalmology, Kanazawa Medical University, Ishikawa
关键词
ACCURACY TEST; SCHEIMPFLUG PHOTOGRAPHY; BIOMETRY; ANTERIOR EYE SEGMENT; PHANTOM EYE; IOL POSITIONING;
D O I
10.1159/000267512
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The accuracy of biometrical data obtained from Scheimpflug images through an Anterior Eye Segment Analysis System, EAS-1000, was examined using phantom eyes and eyes with implanted IOLs. Phantom eyes were composed of hard contact lenses, intraocular lenses and distilled water, which were applied to the cornea, the crystalline lens and the aqueous humor and vitreous, respectively. IOLs inserted into phantom eyes had different positionings with tilting ranges from 0 to 10 degrees and decentration ranges from 0 to 1.0 mm. In the in vivo examination, 20 subjects were examined. The error range of tilting and decentration examined in the phantom eyes was +/- 0.3 degrees and +/- 0.1 mm, respectively. In the examination of the human subjects, the curvatures of the anterior and posterior surfaces of the implanted IOLs and IOL thickness were measured and the obtained data were compared with specific data. In these measurements, each of the paired values were statistically of no significant difference. The errors ranged from 3 to 9%.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 11 条
[1]   CHANGE IN SHAPE AND INTERNAL FORM OF LENS OF EYE ON ACCOMMODATION [J].
BROWN, N .
EXPERIMENTAL EYE RESEARCH, 1973, 15 (04) :441-459
[2]  
DRAGOMIRESCU V, 1978, INTDSCPL TOPICS GERO, V13, P118
[3]   BIOMETRY OF THE ANTERIOR EYE SEGMENT BY SCHEIMPFLUG PHOTOGRAPHY [J].
HOCKWIN, O ;
WEIGELIN, E ;
LASER, H ;
DRAGOMIRESCU, V .
OPHTHALMIC RESEARCH, 1983, 15 (02) :102-108
[4]   IMPROVED BIOMETRY OF THE ANTERIOR EYE SEGMENT [J].
KAMPFER, T ;
WEGENER, A ;
DRAGOMIRESCU, V ;
HOCKWIN, O .
OPHTHALMIC RESEARCH, 1989, 21 (03) :239-248
[5]   REPRODUCIBILITY OF DATA OBTAINED BY A NEWLY DEVELOPED ANTERIOR EYE SEGMENT ANALYSIS SYSTEM, EAS-1000 [J].
SAKAMOTO, Y ;
SASAKI, K ;
NAKAMURA, Y ;
WATANABE, N .
OPHTHALMIC RESEARCH, 1992, 24 :10-20
[6]  
SAKAMOTO Y, 1992, JPN J CLIN OPHTHAL, V46, P312
[7]  
SAKAMOTO Y, 1990, J OPHTHALMOL OPT SOC, V11, P102
[8]   THE MULTIPURPOSE CAMERA - A NEW ANTERIOR EYE SEGMENT ANALYSIS SYSTEM [J].
SASAKI, K ;
SAKAMOTO, Y ;
SHIBATA, T ;
EMORI, Y .
OPHTHALMIC RESEARCH, 1990, 22 :3-8
[9]  
SASAKI K, 1986, J OPHTHALMIC PHOTOGR, V9, P112
[10]   LENS BIOMETRY ACCORDING TO AGE AND CATARACT MORPHOLOGY - EVALUATION OF SCHEIMPFLUG PHOTOGRAPHS OF THE ANTERIOR SEGMENT [J].
SHIBATA, T ;
HOCKWIN, O ;
WEIGELIN, E ;
KLEIFELD, O ;
DRAGOMIRESCU, V .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1984, 185 (01) :35-42