ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN - CHOOSING EMBOLIC MATERIALS TO ENHANCE SAFETY AND EASE OF EXCISION

被引:56
作者
PURDY, PD
BATJER, HH
RISSER, RC
SAMSON, D
机构
[1] UNIV TEXAS, HLTH SCI CTR, SW MED SCH, DEPT NEUROSURG, DALLAS, TX 75235 USA
[2] UNIV TEXAS, HLTH SCI CTR, SW MED SCH, DEPT NEUROL, DALLAS, TX 75235 USA
[3] UNIV TEXAS, HLTH SCI CTR, SW MED SCH, ACAD COMP SERV, DALLAS, TX 75235 USA
关键词
ARTERIOVENOUS MALFORMATION; CEREBROVASCULAR SYSTEM; CYANOACRYLATE; EMBOLIZATION; POLYVINYL ALCOHOL;
D O I
10.3171/jns.1992.77.2.0217
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The authors report their experience with surgical resection of 108 previously embolized arteriovenous malformations (AVM's). Embolization was performed via only transfemoral catheterization in 70 lesions and via the surgical exposure of feeding vessels in 32. The remaining six patients were referred for resection following silicone sphere embolization elsewhere. Materials used included polyvinyl alcohol (PVA) foam, platinum microcoils, detachable silicone balloons, surgical silk, a mixture of 33% ethanol and microfibrillar collagen, and isobutyl cyanoacrylate (IBCA). It is believed that proximal arterial occlusion with balloons is an inferior choice for preresection embolization, because the technical difficulty of placement is high and the nidus of the AVM is unaffected. Vascular coagulation and section and AVM retraction are more difficult with IBCA; therefore, this is also considered an inferior choice. Among the materials studied, the combination of PVA for distal occlusion and microcoils for proximal occlusion appears to be the superior choice. Fewer complications (stroke or hemorrhage) are seen when intra-arterial Amytal (amobarbital) testing is used to guide the embolization. Data regarding toxicity, oncogenicity, and vascular metabolism or recanalization associated with PVA, IBCA, and n-butyl cyanoacrylate are reviewed.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 48 条
[1]   STAGED TREATMENT OF ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN [J].
ANDREWS, BT ;
WILSON, CB .
NEUROSURGERY, 1987, 21 (03) :314-323
[2]   CHRONIC VASCULAR REACTIONS TO STEEL COIL OCCLUSION DEVICES [J].
BARTH, KH ;
STRANDBERG, JD ;
KAUFMAN, SL ;
WHITE, RI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (03) :455-458
[3]  
BERENSTEIN A, 1987, J NEUROSURG, V67, P318
[4]   CATHETER AND MATERIAL SELECTION FOR TRANS-ARTERIAL EMBOLIZATION - TECHNICAL CONSIDERATIONS .2. MATERIALS [J].
BERENSTEIN, A ;
KRICHEFF, II .
RADIOLOGY, 1979, 132 (03) :631-639
[5]  
BERENSTEIN AB, 1989, AM J NEURORADIOL, V10, P883
[6]  
BONUTTI PM, 1988, CLIN ORTHOP RELAT R, V229, P241
[7]  
BROTHERS MF, 1989, AM J NEURORADIOL, V10, P777
[8]   DOSE-RESPONSE STUDIES OF GENTAMICIN-NEPHROTOXICITY IN RATS WITH EXPERIMENTAL RENAL DYSFUNCTION .2. POLYVINYL-ALCOHOL GLOMERULOPATHY [J].
CARVER, MP ;
MONTEIRORIVIERE, NA ;
BROWN, TT ;
RIVIERE, JE .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1985, 80 (02) :264-273
[9]   MODIFICATION OF CYANOACRYLATE FOR THERAPEUTIC EMBOLIZATION - PRELIMINARY EXPERIENCE [J].
CROMWELL, LD ;
KERBER, CW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 132 (05) :799-801
[10]   HISTOLOGIC ANALYSIS OF TISSUE-RESPONSE TO BUCRYLATE-PANTOPAQUE MIXTURE [J].
CROMWELL, LD ;
FREENY, PC ;
KERBER, CW ;
KUNZ, LL ;
HARRIS, AB ;
SHAW, CM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (03) :627-631