Subjective indoor air quality in schools - The influence of high room temperature, carpeting, fleecy wall materials and volatile organic compounds (VOC)

被引:45
作者
Norback, D
机构
[1] Department of Occupational and Environmental Medicine, University Hospital, Uppsala
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1995年 / 5卷 / 04期
关键词
air humidity; carbon dioxide; fleecy wall material; psychosocial factors; respirable dust; volatile organic compounds (VOC);
D O I
10.1111/j.1600-0668.1995.00003.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There is a growing concern about indoor air quality (IAQ) in schools. We have studied relations between subjective indoor air quality (SIAQ) and measured IAQ among school personnel (N = 97) in six mid-Swedish primary schools. Information on SIAQ and the psychosocial work environment teas measured by a self-administered questionnaire, using analogue rating scales. Indoor exposures were quantified by hygienic measurements. Perception of high room temperature was related to a poor climate of cooperation, fleecy wall materials, and the concentration of volatile organic compounds (VOC), including xylene, limonene, and butanols. Perception of air dryness was related to atopy, work stress, poor climate of cooperation, high room temperature, low air humidity, and high VOC concentration, including, limonene, and n-alkanes. Perception of dusty air was related to work stress, the role of schoolteacher, and exposure to 2-ethyl-1-hexanol. No relations were found between SIAQ and CO2, building age, or respirable dust. To achieve a good SIAQ, room temperature should be Kept at a maximum of 22 degrees C, and exposure to VOCs and fleecy materials should be minimized. Finally, a sound psychosocial work climate is essential for the perception of a good physical indoor climate.
引用
收藏
页码:237 / 246
页数:10
相关论文
共 27 条
[1]   CHEMOSORPTION SAMPLING AND ANALYSIS OF FORMALDEHYDE IN AIR - INFLUENCE ON RECOVERY DURING THE SIMULTANEOUS SAMPLING OF FORMALDEHYDE, PHENOL, FURFURAL AND FURFURYL ALCOHOL [J].
ANDERSSON, K ;
HALLGREN, C ;
LEVIN, JO ;
NILSSON, CA .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1981, 7 (04) :282-289
[2]   AIR-POLLUTION SOURCES IN OFFICES AND ASSEMBLY HALLS, QUANTIFIED BY THE OLF UNIT [J].
FANGER, PO ;
LAURIDSEN, J ;
BLUYSSEN, P ;
CLAUSEN, G .
ENERGY AND BUILDINGS, 1988, 12 (01) :7-19
[4]  
GEBSKI V, 1992, SPIDA USERS MANUAL V
[5]   SICK BUILDING SYNDROME, SENSATION OF DRYNESS AND THERMAL COMFORT IN RELATION TO ROOM-TEMPERATURE IN AN OFFICE BUILDING - NEED FOR INDIVIDUAL CONTROL OF TEMPERATURE [J].
JAAKKOLA, JJK ;
HEINONEN, OP ;
SEPPANEN, O .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :163-168
[6]  
Jaakkola JJK, 1991, INDOOR AIR, V1, P111, DOI DOI 10.1111/J.1600-0668.1991.02-12.X
[7]   SENSITIVITY OF THE EYES TO AIRBORNE IRRITANT STIMULI - INFLUENCE OF INDIVIDUAL CHARACTERISTICS [J].
KJAERGAARD, S ;
PEDERSEN, OF ;
MOLHAVE, L .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1992, 47 (01) :45-50
[8]  
LUNDIN L, 1991, BUILDING RELATED CAU
[9]  
Molhave L., 1993, INDOOR AIR, V3, P155, DOI [10.1111/j.1600-0668.1993.t01-1-00002.x, DOI 10.1111/J.1600-0668.1993.T01-1-00002.X]
[10]   A LONGITUDINAL-STUDY RELATING CARPETING WITH SICK BUILDING SYNDROME [J].
NORBACK, D ;
TORGEN, M .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :129-135