EFFECT OF HYDROGEL LENS WEAR ON TEAR FILM STABILITY

被引:59
作者
FABER, E
GOLDING, TR
LOWE, R
BRENNAN, NA
机构
[1] Corneal Biophysics Laboratory, Department of Optometry, University of Melbourne, Parkville
关键词
HYDROGEL CONTACT LENS; NONINVASIVE BREAKUP TIME (NIBUT); POSTLENS TEAR FILM; PRECORNEAL TEAR FILM; PRELENS TEAR FILM; WATER CONTENT;
D O I
10.1097/00006324-199105000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Noninvasive break-up time (NIBUT) of the tears was measured in a controlled, randomized, double-masked study to assess: (1) the stability of the prelens tear film during wear of new high and low water content lenses and (2) the stability of the precorneal tear film following lens removal after 1 h of wear. The prelens tear film NIBUT of 6 subjects was found to be relatively constant over a 1-h wearing period, averaging 6.1 +/- 1.1 s (mean +/- SEM). These values were significantly (Scheffe's S test, p < 0.05) lower than those recorded for the precorneal tear film before lens insertion (33.5 +/- 10.6; mean +/- SEM), although 85% of prelens tear film NIBUT's were greater than the 3-s average interblink period reported previously for soft lens wearers. After lens removal, precorneal tear film NIBUT was reduced significantly compared to prewear levels (Scheffe's S test, p < 0.05) for up to 15 min. Application of the monomolecular growth model to the NIBUT recovery data revealed a half-time for recovery of 6.0 min, with recovery 95% complete 25.8 min after lens removal. Lens type was not a significant factor in tear film stability, either during wear or after lens removal. The basis for reduced precorneal tear film NIBUT after lens removal is unknown; however, a disruption of the mucin layer coating the corneal epithelium is the most likely mechanism. Indeed, the technique of measuring precorneal tear film NIBUT after lens removal may be a useful determinant of the extent to which contact lens wear disrupts the precorneal mucin layer, providing an indication of the susceptibility of the cornea to a variety of complications.
引用
收藏
页码:380 / 384
页数:5
相关论文
共 25 条
[1]  
Nilsson S., Ersson L., Contact lens wear in dry environments, Acta Ophthalmol (Kbh), 64, pp. 221-225, (1986)
[2]  
Norn M.S., Desiccation of the pre-corneal film. I. Corneal wetting-time, Acta Ophthalmol (Kbh), 47, pp. 865-880, (1969)
[3]  
Lemp M.A., Hamill J.R., Factors affecting tear film breakup in normal eyes, Arch Ophthalmol, 89, pp. 103-105, (1973)
[4]  
Refojo M.F., Korb D.R., Silverman H.I., Clinical evaluation of a new fluorescent dye for hydrogel lenses, J am Optom Assoc, 43, pp. 321-326, (1972)
[5]  
Doane M.G., An Instrument for in vivo tear film interferometry, Optom Vis Sci, 66, pp. 383-388, (1989)
[6]  
Guillon J.P., Gulllon M., Tear film examination of the contact lens patient, Contax, May, pp. 14-18, (1988)
[7]  
Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J., A non-invasive instrument for clinical assessment of the pre-corneal tear film stability, Curr Eye Res, 4, pp. 1-7, (1985)
[8]  
Hirji N., Patel S., Callander M., Human tear film pre-rupture phase time (TP-RPT)-A non-invasive technique for evaluating the pre-corneal tear film using a novel keratometer mire, Ophthal Physiol Opt, 9, pp. 139-142, (1989)
[9]  
Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J., Effect of fluorescein instillation on the pre-corneal tear film stability, Curr Eye Res, 4, pp. 9-12, (1985)
[10]  
Patel S., Murray D., McKenzie A., Shearer D.S., McGrath B.D., Effects of fluorescein on tear breakup time and on tear thinning time, Am J Optom Physiol Opt, 62, pp. 188-190, (1985)