IMAGING OF HUMAN BRAIN ACTIVITY AT 0.15 T USING FLUID ATTENUATED INVERSION-RECOVERY (FLAIR) PULSE SEQUENCES

被引:23
作者
HAJNAL, JV
COLLINS, AG
WHITE, SJ
PENNOCK, JM
OATRIDGE, A
BAUDOUIN, CJ
YOUNG, IR
BYDDER, GM
机构
[1] HAMMERSMITH HOSP,ROYAL POSTGRAD MED SCH,ROBERT STEINER MAGNET RESONANCE UNIT,DU CANE RD,LONDON W12 0HS,ENGLAND
[2] PICKER INT LTD,WEMBLEY,MIDDX,ENGLAND
关键词
MAGNETIC RESONANCE IMAGING; FUNCTIONAL NEURO-IMAGING; BRAIN ACTIVATION; VISUAL STIMULATION;
D O I
10.1002/mrm.1910300520
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 3-4% change in signal intensity correlated with visual stimulation was observed in the occipital lobes of three normal volunteers examined with MRI at 0.15 T using fluid attenuated inversion recovery pulse sequences. Similar results were observed at 1.0 T. A double difference technique in which difference images are themselves opposed provided an increase in sensitivity.
引用
收藏
页码:650 / 653
页数:4
相关论文
共 10 条
[1]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[2]   FOCAL PHYSIOLOGICAL UNCOUPLING OF CEREBRAL BLOOD-FLOW AND OXIDATIVE-METABOLISM DURING SOMATOSENSORY STIMULATION IN HUMAN-SUBJECTS [J].
FOX, PT ;
RAICHLE, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (04) :1140-1144
[3]  
FRAHM J, 1992, 11TH P SMRM M BERL, P306
[4]  
GORE JC, 1992, 11TH P ANN SCI M EXH, P1826
[5]  
HAJNAL JV, 1992, 11TH ANN M SOC MAGN, P1023
[6]  
KIM SG, 1992, 11TH ANN M SOC MAGN, P1825
[7]   DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION [J].
KWONG, KK ;
BELLIVEAU, JW ;
CHESLER, DA ;
GOLDBERG, IE ;
WEISSKOFF, RM ;
PONCELET, BP ;
KENNEDY, DN ;
HOPPEL, BE ;
COHEN, MS ;
TURNER, R ;
CHENG, HM ;
BRADY, TJ ;
ROSEN, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) :5675-5679
[8]  
OGAWA S, 1992, 11TH P ANN M SMRM BE, P303
[9]  
TURNER K, 1992, 11TH ANN M BERL, P304
[10]   USE OF FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCES FOR IMAGING THE SPINAL-CORD [J].
WHITE, SJ ;
HAJNAL, JV ;
YOUNG, IR ;
BYDDER, GM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :153-162