HOME MONITORING OF TRANSCUTANEOUS OXYGEN-TENSION IN THE EARLY DETECTION OF HYPOXEMIA IN INFANTS AND YOUNG-CHILDREN

被引:40
作者
POETS, CF [1 ]
SAMUELS, MP [1 ]
NOYES, JP [1 ]
JONES, KA [1 ]
SOUTHALL, DP [1 ]
机构
[1] ROYAL BROMPTON HOSP, NATL HEART & LUNG INST, DEPT PAEDIAT, FULHAM RD, LONDON SW3 6HP, ENGLAND
关键词
D O I
10.1136/adc.66.6.676
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Twenty three patients (age range 0.5-40 months) with recurrent cyanotic episodes underwent physiological recordings, including transcutaneous oxygen tension (TcPo2) from a monitor modified for use at home (Kontron 821S). Of 69 episodes in which the arterial oxygen saturation (Sao2, Nellcor N200) was less-than-or-equal-to 80% for greater-than-or-equal-to 20 seconds and/or central cyanosis was present, the TcPo2 monitor alarmed (less-than-or-equal-to 20 mmHg or 2.67 kPa) in every episode. The pulse oximeter identified hypoxaemia in 62 out of 69 episodes, failing in seven episodes due to signal loss from movement artefact. In only seven of 69 episodes was there an accompanying apnoeic pause (greater-than-or-equal-to 20 seconds), and heart rate fell to less-than-or-equal-to 80 beats/minute in only five of 28 episodes in which an electrocardiogram was recorded. In 32 episodes in which Sao2 fell to less-than-or-equal-to 60%, the TcPo2 monitor alarmed after a median time interval of 16 seconds (maximum time interval 30 seconds). The TcPo2 monitor was then used in an uncontrolled trial at home in 350 patients at increased risk of sudden death and/or hypoxaemia. Indications for monitoring included apparent life threatening events or cyanotic episodes (n = 163), prematurity and prematurity related disorders (n = 86), and sudden unexpected death in one or more siblings (n = 122). The TcPo2 monitor detected cyanotic episodes at home in 81 patients, 52 of whom received vigorous stimulation and/or mouth to mouth resuscitation. Twenty one of these 52 patients had further hypoxaemic episodes documented in hospital with pulse oximetry. In 30 patients, the TcPo2 monitor also identified the gradual development of hypoxaemia, as confirmed by pulse oximetry. Twenty of these needed additional inspired oxygen and six subsequently needed ventilatory support in hospital. This TcPo2 monitor is a reliable detector of both sudden and gradual onset hypoxaemia and is able to be used by parents in the home.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 24 条
[1]  
DAVIDSON WSL, 1986, PEDIATRICS, V77, P451
[2]   IMPACT OF HOME MONITORING FOR SUDDEN-INFANT-DEATH-SYNDROME ON FAMILY-LIFE - A CONTROLLED-STUDY [J].
DESMAREZ, C ;
BLUM, D ;
MONTAUK, L ;
KAHN, A .
EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (02) :159-161
[3]  
EBERHARD P, 1978, ACTA ANAESTH SCAND, P20
[4]   PULSE OXIMETRY IN PEDIATRIC INTENSIVE-CARE - COMPARISON WITH MEASURED SATURATIONS AND TRANS-CUTANEOUS OXYGEN-TENSION [J].
FANCONI, S ;
DOHERTY, P ;
EDMONDS, JF ;
BARKER, GA ;
BOHN, DJ .
JOURNAL OF PEDIATRICS, 1985, 107 (03) :362-366
[5]   SUDDEN INFANT DEATH SYNDROME AND BIRTH-WEIGHT [J].
GRETHER, JK ;
SCHULMAN, J .
JOURNAL OF PEDIATRICS, 1989, 114 (04) :561-567
[6]   RISK OF SUDDEN-INFANT-DEATH-SYNDROME IN SUBSEQUENT SIBLINGS [J].
GUNTHEROTH, WG ;
LOHMANN, R ;
SPIERS, PS .
JOURNAL OF PEDIATRICS, 1990, 116 (04) :520-524
[7]   PROSPECTIVE ASSESSMENT OF RECURRENCE RISK IN SUDDEN INFANT DEATH SYNDROME SIBLINGS [J].
IRGENS, LM ;
SKJAERVEN, R ;
PETERSON, DR .
JOURNAL OF PEDIATRICS, 1984, 104 (03) :349-351
[8]  
Lafeber H N, 1987, Adv Exp Med Biol, V220, P181
[9]  
LESOUEF PN, 1978, ACTA ANAESTH SCAND, P91
[10]  
LIGHT MJ, 1989, HAWAII MED J, V8, P304