USE OF ACTIVATION TECHNIQUES FOR THE MEASUREMENT OF NEUTRON YIELDS FROM DEUTERIUM PLASMAS AT THE JOINT EUROPEAN TORUS

被引:41
作者
JARVIS, ON
CLIPSHAM, EW
HONE, MA
LAUNDY, BJ
PILLON, M
RAPISARDA, M
SADLER, GJ
VANBELLE, P
VERSCHUUR, KA
机构
[1] ENTE NAZL ENERGIA ATOM,DIV APPL NEUROTRON,ASSOC EURATOM,NUCL RES CTR,FRASCATI,ITALY
[2] ECN,PETTEN,NETHERLANDS
来源
FUSION TECHNOLOGY | 1991年 / 20卷 / 03期
关键词
TOKAMAKS; NEUTRON CALIBRATIONS; ACTIVATION TECHNIQUES;
D O I
10.13182/FST91-A29668
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The time dependence of the 2.5-MeV neutron emission from the Joint European Torus (JET) is reliably measured using fission chambers. The absolute calibration of these chambers is required to an accuracy of 10% or better for a range of intensities that may cover six or more decades. At JET, this calibration is now achieved by use of activation techniques, the most convenient of which involves fissionable materials (thorium and uranium) and delayed neutron counting. Because delayed neutron counting is unfamiliar in the fusion community, particular care is taken to obtain confirmation of the results based on this method by comparison with measurements made using the conventional activation procedure (involving indium, nickel, and zinc as target materials). As the activation measurements can be influenced appreciably by the weak emission of 14-MeV neutrons, this contribution is measured separately using high threshold energy activation reactions (in copper and silicon). Neutron transport calculations are employed to relate the measured local fluences of both 2.5- and 14-MeV neutrons to the total yields from the plasma. Absolute calibration accuracies of 6 and 8% are claimed for 2.5- and 14-MeV neutron yields, respectively; the accuracy of the 14-MeV to 2.5-MeV yield ratios is 6%.
引用
收藏
页码:265 / 284
页数:20
相关论文
共 25 条
  • [1] ADAMS JM, 1989, 16TH P EPS C VEN B, V13, P63
  • [2] TIME RESOLVED MEASUREMENTS OF TRITON BURNUP IN JET PLASMAS
    CONROY, S
    JARVIS, ON
    SADLER, G
    HUXTABLE, GB
    [J]. NUCLEAR FUSION, 1988, 28 (12) : 2127 - 2134
  • [3] DHONDT P, 1986, CENSCK528007510 CTR
  • [4] ELEVANT T, 1989, JETP8976 JET JOINT U
  • [5] GILLIAM DM, 1984, 5TH P S REACT DOS GE, P867
  • [6] TFTR EPITHERMAL NEUTRON DETECTOR SYSTEM - RECALIBRATION AND EFFECT OF NONISOTROPIC NEUTRON EMISSION
    HENDEL, HW
    JASSBY, DL
    BOSCH, HS
    BARNES, CW
    JOHNSON, LC
    MURPHY, TJ
    NIESCHMIDT, EB
    SAITO, T
    STRACHAN, JD
    TAIT, GD
    YOUNG, KM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) : 1682 - 1684
  • [7] IN-VESSEL CALIBRATION OF THE JET NEUTRON MONITORS USING A CF-252 NEUTRON SOURCE - DIFFICULTIES EXPERIENCED
    JARVIS, ON
    SADLER, G
    VANBELLE, P
    ELEVANT, T
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10) : 3172 - 3174
  • [8] JARVIS ON, 1985, JETIR8506 JET JOINT
  • [9] JARVIS ON, 1988, JETR8805 JET JOINT U
  • [10] TRITON BURNUP MEASUREMENTS IN JET USING A NEUTRON-ACTIVATION TECHNIQUE
    KALLNE, J
    BATISTONI, P
    GORINI, G
    HUXTABLE, GB
    PILLON, M
    PODDA, S
    RAPISARDA, M
    [J]. NUCLEAR FUSION, 1988, 28 (07) : 1291 - 1297