ULTRAHIGH Q PENDULUM SUSPENSIONS FOR GRAVITATIONAL-WAVE DETECTORS

被引:30
作者
BLAIR, DG
JU, L
NOTCUTT, M
机构
[1] Department of Physics, University of Western Australia, Nedlands
关键词
D O I
10.1063/1.1143974
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pendulum suspensions for laser interferometer gravitational wave detectors need to have an extremely high Q factor to minimize Brownian motion noise. In this paper we analyze the limits to the Q factor of the compound pendulum. We show that the observed acoustic loss of niobium can allow pendulum Q factors of 10(10) to be achieved. This should enable a 3 km terrestrial laser interferometer detector to achieve strain sensitivity of 10(-22)/square-root Hz at frequencies as low as 10 Hz. At cryogenic temperatures Q factors up to 10(12) should be achievable.
引用
收藏
页码:1899 / 1904
页数:6
相关论文
共 28 条
  • [1] LIGO - THE LASER-INTERFEROMETER-GRAVITATIONAL-WAVE-OBSERVATORY
    ABRAMOVICI, A
    ALTHOUSE, WE
    DREVER, RWP
    GURSEL, Y
    KAWAMURA, S
    RAAB, FJ
    SHOEMAKER, D
    SIEVERS, L
    SPERO, RE
    THORNE, KS
    VOGT, RE
    WEISS, R
    WHITCOMB, SE
    ZUCKER, ME
    [J]. SCIENCE, 1992, 256 (5055) : 325 - 333
  • [2] ANDERSON RA, 1967, FUNDAMENTALS VIBRATI
  • [3] BAGDASAROV KS, 1977, VESTN MOSK U FIZ AS, V9, P98
  • [4] CRYOGENIC LOW ACOUSTIC LOSS BONDING OF NIOBIUM WITH APPLICATION TO GRAVITATIONAL-RADIATION DETECTORS
    BLAIR, DG
    RAMM, DK
    [J]. CRYOGENICS, 1986, 26 (05) : 322 - 324
  • [5] BLAIR DG, 1991, DETECTION GRAVITATIO
  • [6] BRAGINSKY VB, 1992, 5 MOSC STAT U DEP PH
  • [7] BRILLET A, COMMUNICATION
  • [8] DREVER RWP, 1991, DETECTION GRAVITATIO, P306
  • [9] FABBRO RD, 1988, REV SCI INSTRUM, V59, P293
  • [10] FERREIRINHO J, 1986, THESIS U W AUSTR