APPARATUS FOR HIGH-PRECISION REPETITIVE SEQUENTIAL OPTICAL MEASUREMENT OF LIVING CELLS

被引:39
作者
DEUTSCH, M
WEINREB, A
机构
[1] Jerome Schottenstein Cellscan Center, Department of Physics, Bar-Llan University, Ramat-Gan
来源
CYTOMETRY | 1994年 / 16卷 / 03期
关键词
FLUORESCEINS; FLUORESCENCE POLARIZATION; LYMPHOCYTES; SPECTROPHOTOMETRY;
D O I
10.1002/cyto.990160305
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A system is described which permits the repetitive spectroscopic measurement of individual cells within a population of many cells, while the location of each cell is preserved during various manipulations of the cells and/or their surrounding medium. The central mechanical feature of the system is the cell carrier, a matrix of apertures in which the cells become trapped. The detector electronics operate in a preset photon counting mode, permitting the measurement of low and high Light intensities with the same degree of precision. The present instrument configuration is specifically designed for the accurate and precise measurement of the polarization of fluorescence of probes within living cells for application to routine performance of the Cercek SCM test for cancer. With modifications, the apparatus can be applied to a wide range of other clinical and research tasks. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:214 / 226
页数:13
相关论文
共 28 条
[1]  
BODDINGTON MM, 1967, BMJ-BRIT MED J, V3, P160
[2]   ACOUSTOOPTIC LASER-SCANNING CYTOMETER [J].
BURGER, D ;
GERSHMAN, R .
CYTOMETRY, 1988, 9 (02) :101-110
[3]   BIOPHYSICAL DIFFERENTIATION BETWEEN LYMPHOCYTES FROM HEALTHY DONORS, PATIENTS WITH MALIGNANT DISEASES AND OTHER DISORDERS [J].
CERCEK, L ;
CERCEK, B ;
FRANKLIN, CI .
BRITISH JOURNAL OF CANCER, 1974, 29 (05) :345-352
[4]   APPLICATION OF PHENOMENON OF CHANGES IN STRUCTUREDNESS OF CYTOPLASMIC MATRIX (SCM) IN DIAGNOSIS OF MALIGNANT DISORDERS - REVIEW [J].
CERCEK, L ;
CERCEK, B .
EUROPEAN JOURNAL OF CANCER, 1977, 13 (09) :903-915
[5]   TUMOR SPECIFICITY OF THE SCM TEST FOR CANCER-DIAGNOSIS [J].
CHAITCHIK, S ;
ASHER, O ;
DEUTSCH, M ;
WEINREB, A .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1985, 21 (10) :1165-1170
[6]   CESAR - CERVICAL SMEAR ANALYSER AND READER - A NEW APPROACH TO EVALUATING CELLS IN CYTOLOGICAL PREPARATIONS [J].
DAWSON, IMP ;
HEANLEY, CP ;
HEBERPER.AC ;
TYLKO, JK .
JOURNAL OF CLINICAL PATHOLOGY, 1967, 20 (05) :724-&
[7]  
DEGROOTH BG, 1985, CYTOMETRY, V6, P226
[8]   VALIDATION OF THE SCM-TEST FOR THE DIAGNOSIS OF CANCER [J].
DEUTSCH, M ;
WEINREB, A .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1983, 19 (02) :187-193
[9]   DEVELOPMENT OF VIBRATING-MIRROR FLYING SPOT MICROSCOPE FOR ULTRAVIOLET SPECTROPHOTOMETRY [J].
FREED, JJ ;
ENGLE, JL .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 97 (02) :412-&
[10]   PRACTICAL APPLICATION OF COMPUTER PATTERN-RECOGNITION RESEARCH - ABBOTT ADC-500 DIFFERENTIAL CLASSIFIER [J].
GREEN, JE .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :160-173