DETERMINATION OF BENCYCLANE IN HUMAN PLASMA BY MEANS OF CAPILLARY GAS-CHROMATOGRAPHY AND NITROGEN PHOSPHORUS SELECTIVE DETECTION

被引:1
作者
LOHMANN, A
DIEKMANN, N
WALTERS, R
KRAFT, R
机构
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 564卷 / 01期
关键词
D O I
10.1016/0378-4347(91)80092-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific method for the determination of bencyclane in human plasma is presented. Bencyclane was extracted from human plasma with two 3-ml volumes of isooctane and was shaken for 10 min. The organic phase was separated and evaporated to dryness at 40-degrees-C under a nitrogen stream. The residue was dissolved and an aliquot was injected into the gas chromatograph. The separation was performed with a DB-17 column with helium as the carrier gas. Nitrogen-selective detection was performed. The quantification was performed with the signal output. The limit of detection was 1 ng/ml.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 4 条
[1]  
ECKARD R, 1985, ARZNEIMITTEL-FORSCH, V35-2, P1587
[2]  
GIELSDORF W, 1984, ARZNEIMITTEL-FORSCH, V34-1, P290
[3]   GAS-LIQUID CHROMATOGRAPHIC EVALUATION OF BENCYCLANE IN BIOLOGICAL SAMPLES FOR PHARMACOKINETIC AND BIOAVAILABILITY INVESTIGATIONS - COMPARISON OF 2 ANALYTICAL METHODS [J].
MARZO, A ;
TREFFNER, E ;
QUADRO, G ;
RAPELLI, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 343 (01) :77-84
[4]  
MOHRI ZI, 1985, J PHARMACOBIO-DYNAM, V8, P227