ANISOTROPY FUNCTIONS FOR PD-103, I-125, AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES

被引:56
作者
NATH, R
MEIGOONI, AS
MUENCH, P
MELILLO, A
机构
[1] Division of Radiation Oncology, Washington University School of Medicine, Saint Louis
[2] Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06510
关键词
I-125; PD-103; IR-192; TLD; INTERSTITIAL BRACHYTHERAPY;
D O I
10.1118/1.597110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Anisotropy of dose distributions around Pd-103, I-125, and Ir-192 sources for interstitial brachytherapy was examined. Dose rates around I-125 models 6702 and 6711 and Ir-192 sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data for I-125 and Ir-192 and the previously published measured data for Pd-103, isodose rate contours were determined using a bivariate interpolation and smooth surface fitting algorithm. The anisotropy functions, F(r,theta), as defined by the Interstitial Collaborative Working Group (ICWG) for each source, were determined. Also, 4pi-averaged anisotropy factors, phi(an)(r), for use in point source approximation, have been calculated at radial distances varying from 1-10 cm for Pd-103, I-125, and Ir-192 sources. The anisotropy factors had average values of 0.90, 0.93, 0.95, and 0.98 for Pd-103, I-125 model 6711, model 6702, and Ir-192, respectively. The anisotropy factors determined from dose measurements in phantom are observed to be closer to unity than from those determined previously from in-air measurements. This can be attributed to the smoothing of two-dimensional dose distributions due to the presence of more scattered photons in the phantom measurements compared to in-air measurements. Because in-phantom measurements simulate more closely the brachytherapy patient, data from these experiments are recommended for a more accurate determination of dose distributions around clinical brachytherapy implants. In this work, we present a complete set of source data for two-dimensional dosimetry following the ICWG formalism.
引用
收藏
页码:1465 / 1473
页数:9
相关论文
共 23 条
[1]  
Akima H., 1978, ACM Transactions on Mathematical Software, V4, P148, DOI 10.1145/355780.355786
[2]  
Anderson LL, 1990, INTERSTITIAL BRACHYT
[3]   TWO-DIMENSIONAL DOSE DISTRIBUTION AROUND A COMMERCIAL I125 SEED [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1988, 15 (01) :56-60
[4]   MONTE-CARLO SIMULATION OF THE DOSE DISTRIBUTION AROUND I-125 SEEDS [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1987, 14 (03) :420-424
[5]   DOSE-RATE DETERMINATION FOR I-125 SEEDS [J].
CHIUTSAO, ST ;
ANDERSON, LL ;
OBRIEN, K ;
SANNA, R .
MEDICAL PHYSICS, 1990, 17 (05) :815-825
[6]   THERMOLUMINESCENT DOSIMETRY FOR PD-103 SEEDS (MODEL 200) IN SOLID WATER PHANTOM [J].
CHIUTSAO, ST ;
ANDERSON, LL .
MEDICAL PHYSICS, 1991, 18 (03) :449-452
[7]   THE 3-DIMENSIONAL DOSE DISTRIBUTION OF I-125 SEEDS IN TISSUE [J].
HARTMANN, GH ;
SCHLEGEL, W ;
SCHARFENBERG, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (06) :693-699
[8]   PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT [J].
LING, CC ;
YORKE, ED ;
SPIRO, IJ ;
KUBIATOWICZ, D ;
BENNETT, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11) :1747-1752
[9]   TWO-DIMENSIONAL DOSE DISTRIBUTION OF I125 SEEDS [J].
LING, CC ;
SCHELL, MC ;
YORKE, ED ;
PALOS, BB ;
KUBIATOWICZ, DO .
MEDICAL PHYSICS, 1985, 12 (05) :652-655
[10]   DIRECTIONAL DEPENDENCE OF RADIATION FLUENCE FROM IR-192 AND AU-198 SOURCES [J].
LING, CC ;
GROMADZKI, ZC ;
RUSTGI, SN ;
CUNDIFF, JH .
RADIOLOGY, 1983, 146 (03) :791-792