NEUTRON DISCREPANCIES IN THE DS86 HIROSHIMA DOSIMETRY SYSTEM

被引:72
作者
STRAUME, T
EGBERT, SD
WOOLSON, WA
FINKEL, RC
KUBIK, PW
GOVE, HE
SHARMA, P
HOSHI, M
机构
[1] SCI APPLICAT INT CORP, SAN DIEGO, CA 92121 USA
[2] UNIV ROCHESTER, ROCHESTER, NY 14627 USA
[3] HIROSHIMA UNIV, HIROSHIMA 730, JAPAN
来源
HEALTH PHYSICS | 1992年 / 63卷 / 04期
关键词
HIROSHIMA; DS86; DOSIMETRY; NEUTRONS;
D O I
10.1097/00004032-199210000-00006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
More than a decade has passed since a complete revision was initiated of the radiation doses received by survivors of the Hiroshima and Nagasaki atomic bombings. The new dosimetry system (DS86) was completed in 1986 and adopted shortly thereafter. Overall, DS86 was noted to be a clear improvement over the old dosimetry system. However, based on limited validation measurements, troublesome inconsistencies were suggested for neutrons. Since 1986, a substantial number of additional neutron activation measurements have been made in mineral and metal samples from Hiroshima. Importantly, a large number of measurements have now been made at distances beyond 1 km. Here, inconsistencies between neutron activation measurements and DS86 calculations for Hiroshima are examined using all available measurement data, including new measurements for Cl-36 which extend the measurement range to more than 1.7 km from the epicenter, and Monte Carlo modeling calculations for each sample measured. Results show that thermal neutron activation measured beyond approximately 1 km in Hiroshima (at distances most relevant for radiation-risk evaluation) is two to 10, or more, times higher than that calculated based on DS86. Similar trends observed when comparing results by several independent measurement laboratories, using different analytical methods, suggest that the DS86 calculations for low-energy neutrons are in error. Because of the importance of the Hiroshima data in radiation risk evaluation, this large discrepancy is in need of resolution.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 26 条
[1]  
BOND VP, 1982, CONF810928 TECHN INF
[2]   THE ROCHESTER TANDEM ACCELERATOR MASS-SPECTROMETRY PROGRAM [J].
ELMORE, D ;
KUBIK, PW ;
TUBBS, LE ;
GOVE, HE ;
TENG, R ;
HEMMICK, T ;
CHRUNYK, B ;
CONARD, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 5 (02) :109-116
[3]   ACCELERATOR MASS-SPECTROMETRY WITH FULLY STRIPPED CL-36 IONS [J].
HABERSTOCK, G ;
HEINZL, J ;
KORSCHINEK, G ;
MORINAGA, H ;
NOLTE, E ;
RATZINGER, U ;
KATO, K ;
WOLF, M .
RADIOCARBON, 1986, 28 (2A) :204-210
[4]  
HARVEY JA, 1991, MAY P INT C NUCL DAT, P729
[5]   EU-152 DEPTH PROFILE OF A STONE BRIDGE PILLAR EXPOSED TO THE HIROSHIMA ATOMIC-BOMB - EU-152 ACTIVITIES FOR ANALYSIS OF THE NEUTRON-SPECTRUM [J].
HASAI, H ;
IWATANI, K ;
SHIZUMA, K ;
HOSHI, M ;
YOKORO, K ;
SAWADA, S ;
KOSAKO, T ;
MORISHIMA, H .
HEALTH PHYSICS, 1987, 53 (03) :227-239
[6]   ESTIMATION OF AIR DOSE FROM ATOMIC BOMBS IN HIROSHIMA AND NAGASAKI [J].
HASHIZUME, T ;
MARUYAMA, T ;
SHIRAGAI, A ;
TANAKA, E ;
IZAWA, M ;
KAWAMURA, S ;
NAGAOKA, S .
HEALTH PHYSICS, 1967, 13 (02) :149-+
[7]  
HASHIZUME T, 1983, US JAPAN JOINT WORKS, P3
[8]  
HASKELL EH, 1983, 2 US JAP JOINT REASS, P32
[9]  
HOOTS S, 1984, UCRL90095 LAWR LIV N
[10]  
HOSHI M, 1989, HEALTH PHYS, V57, P831