ELECTROCHEMICAL DISINFECTION OF BACTERIA IN DRINKING-WATER USING ACTIVATED CARBON-FIBERS

被引:50
作者
MATSUNAGA, T
NAKASONO, S
KITAJIMA, Y
HORIGUCHI, K
机构
[1] Department of Biotechnology, Tokyo University of Agriculture and Technology, Tokyo, 184, Koganei
关键词
DISINFECTION; ESCHERICHIA COLI; WATER DISINFECTION; ACTIVATED CARBON FIBER;
D O I
10.1002/bit.260430511
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A novel electrochemical reactor employing activated carbon fiber (ACF) electrodes was constructed for disinfecting bacteria in drinking water. Escherichia coli adsorbed preferentially onto ACF rather than to carbon-cloth or granular-activated carbon. E. coli cells, which adsorbed onto the ACF, were killed electrochemically when a potential of 0.8 V vs. a saturated calomel electrode (SCE) was applied. Drinking water was passed through the reactor in stop-flow mode: 2 mL/min for 12 h, 0 L/min for 24 h, and 1 mL/min for 6 h. At an applied potential of 0.8 V vs. SCE, viable cell concentration remained below 30 cells/mL. In the absence of an applied potential, bacteria grew to a maximum concentration of 9.5 x 10(3) cells/mL. After continuous operation at 0.8 V vs. SCE, cells adsorbed onto the ACF could not be observed by scanning electron microscopy. In addition, chlorine in drinking water was completely removed by the reactor. Therefore, clean and efficient inactivation of bacteria in drinking water was successfully performed. (C) 1994 John Wiley and Sons, Inc.
引用
收藏
页码:429 / 433
页数:5
相关论文
共 27 条
[1]   ASSESSMENT OF BACTERIAL-GROWTH AND TOTAL ORGANIC-CARBON REMOVAL ON GRANULAR ACTIVATED CARBON CONTACTORS [J].
BANCROFT, K ;
MALONEY, SW ;
MCELHANEY, J ;
SUFFET, IH ;
PIPES, WO .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 46 (03) :683-688
[2]   INACTIVATION OF PARTICLE-ASSOCIATED COLIFORMS BY CHLORINE AND MONOCHLORAMINE [J].
BERMAN, D ;
RICE, EW ;
HOFF, JC .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1988, 54 (02) :507-512
[3]   PREDOMINANT BACTERIAL GENERA IN ANTIGRANULOCYTES ACTIVATED CARBON WATER-TREATMENT SYSTEMS [J].
BURLINGAME, GA ;
SUFFET, IH ;
PIPES, WO .
CANADIAN JOURNAL OF MICROBIOLOGY, 1986, 32 (03) :226-230
[4]   BACTERIA ASSOCIATED WITH ANTIGRANULOCYTES ACTIVATED CARBON PARTICLES IN DRINKING-WATER [J].
CAMPER, AK ;
LECHEVALLIER, MW ;
BROADAWAY, SC ;
MCFETERS, GA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1986, 52 (03) :434-438
[5]   ATTACHMENT AS A FACTOR IN THE PROTECTION OF ENTEROBACTER-CLOACAE FROM CHLORINATION [J].
HERSON, DS ;
MCGONIGLE, B ;
PAYER, MA ;
BAKER, KH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (05) :1178-1180
[6]  
KITAJIMA Y, 1988, DENKI KAGAKU, V52, P1082
[7]   DISINFECTION OF BACTERIA ATTACHED TO GRANULAR ACTIVATED CARBON [J].
LECHEVALLIER, MW ;
HASSENAUER, TS ;
CAMPER, AK ;
MCFETERS, GA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (05) :918-923
[8]   INACTIVATION OF BIOFILM BACTERIA [J].
LECHEVALLIER, MW ;
CAWTHON, CD ;
LEE, RG .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1988, 54 (10) :2492-2499
[9]  
LING JT, 1976, J AM WATER WORKS ASS, V68, P659
[10]   DETECTION OF MICROBIAL-CELLS BY CYCLIC VOLTAMMETRY [J].
MATSUNAGA, T ;
NAMBA, Y .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :798-801