AN IMMUNOSENSOR FOR SYPHILIS SCREENING BASED ON SURFACE-PLASMON RESONANCE

被引:37
作者
SEVERS, AH [1 ]
SCHASFOORT, RBM [1 ]
SALDEN, MHL [1 ]
机构
[1] EURO-DIAGNOST BV,7303 GC APELDOORN,NETHERLANDS
关键词
IMMUNOSENSOR; SURFACE PLASMON RESONANCE; SYPHILIS; TREPONEMA-PALLIDUM MEMBRANE PROTEIN-A;
D O I
10.1016/0956-5663(93)85031-I
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper the development of a surface plasmon resonance (SPR) immunosensor for syphilis screening is described. This immunosensor is based on the detection of antibodies in serum against the causative organism Treponema pallidum. In order to achieve selectivity a recombinant Treponema pallidum membrane protein A (TmpA) was used. This antigen can react with antibodies to T. pallidum, present in serum of syphilitic patients. Reproducible results have been obtained, using a 'sandwich SPR' method: binding of a sandwich antibody to the treponemal antibody after serum incubation was measured in real time while the binding was taking place. The SPR results obtained from ten blind-coded sera corresponded well with classical syphilis tests (Treponema pallidum haemagglutination assay (TPHA), fluorescent treponemal antibody-absorbed test (FTA-ABS), venereal diseases research laboratory flocculation test (VDRL) and TmpA-based enzyme-linked immunosorbent assay (TmpA-ELISA)). Preliminary experiments showed that direct measurement of serum (in the 'one step SPR') is not yet possible, probably as a result of non-uniformity of serum samples. The application of latex beads is considered to solve this problem.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 7 条
[1]   SURFACE-PLASMON RESONANCE APPLIED TO IMMUNOSENSING [J].
DANIELS, PB ;
DEACON, JK ;
EDDOWES, MJ ;
PEDLEY, DG .
SENSORS AND ACTUATORS, 1988, 15 (01) :11-18
[2]   SENSITIVITY AND SPECIFICITY OF AN ENZYME-LINKED IMMUNOSORBENT-ASSAY USING THE RECOMBINANT DNA-DERIVED TREPONEMA-PALLIDUM PROTEIN TMPA FOR SERODIAGNOSIS OF SYPHILIS AND THE POTENTIAL USE OF TMPA FOR ASSESSING THE EFFECT OF ANTIBIOTIC-THERAPY [J].
IJSSELMUIDEN, OE ;
SCHOULS, LM ;
STOLZ, E ;
AELBERS, GNM ;
AGTERBERG, CM ;
TOP, J ;
VANEMBDEN, JDA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (01) :152-157
[3]   SURFACE-PLASMON RESONANCE FOR GAS-DETECTION AND BIOSENSING [J].
LIEDBERG, B ;
NYLANDER, C ;
LUNDSTROM, I .
SENSORS AND ACTUATORS, 1983, 4 (02) :299-304
[4]  
Raether H, 1977, PHYS THIN FILMS, V9, P145
[5]   OPTICAL IMMUNOSENSING SYSTEMS - MEETING THE MARKET NEEDS [J].
ROBINSON, GA .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :183-191
[6]  
SCHASFOORT RBM, 1990, Patent No. 9100073
[7]  
SEIDL MD, 1990, TRANSFUSION, V9, P773