SIMPLE AND ACCURATE WAY FOR ESTIMATING TOTAL AND SEGMENTAL ARTERIAL COMPLIANCE - THE PULSE PRESSURE METHOD

被引:124
作者
STERGIOPULOS, N [1 ]
MEISTER, JJ [1 ]
WESTERHOF, N [1 ]
机构
[1] FREE UNIV AMSTERDAM,INST CARDIOVASC RES,PHYSIOL LAB,1007 MC AMSTERDAM,NETHERLANDS
关键词
WINDKESSEL MODEL; COMPUTER SIMULATION; NONLINEAR ARTERIAL SYSTEM; INPUT IMPEDANCE;
D O I
10.1007/BF02368245
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We derived and tested a new, simple, and accurate method to estimate the compliance of the entire arterial tree and parts thereof. The method requires the measurements of pressure and flow and is based on fitting the pulse pressure (systolic minus diastolic pressure) predicted by the two-element windkessel model to the measured pulse pressure. We show that the two-element windkessel model accurately describes the modulus of the input impedance at low harmonics (0-4th) of the heart rate so that the gross features of the arterial pressure wave, including pulse pressure, are accounted for. The method was tested using a distributed nonlinear model of the human systemic arterial tree. Pressure and flow were calculated in the ascending aorta, thoracic aorta, common carotid, and iliac artery. In a linear version of the systemic model the estimated compliance was within 1% of the compliance at the first three locations. In the iliac artery an error of 7% was found. In a nonlinear version, we compared the estimates of compliance with the average compliance over the cardiac cycle and the compliance at the mean working pressure. At the first three locations we found the estimated and ''actual'' compliance to be within 12% of each other. In the iliac artery the error was larger. We also investigated an increase and decrease in heart rate, a decrease in wall elasticity and exercise conditions. In all cases the estimated total arterial compliance was within 10% of mean compliance. Thus, the errors result mainly from the nonlinearity of the arterial system. Segmental compliance can be obtained by subtraction of compliance determined at two locations.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 17 条
[1]   PRESSURE AND FLOW GENERATED BY LEFT VENTRICLE AGAINST DIFFERENT IMPEDANCES [J].
ELZINGA, G ;
WESTERHOF, N .
CIRCULATION RESEARCH, 1973, 32 (02) :178-186
[2]  
Frank O., 1899, 1 ABHANDLUNG BIOL, P483, DOI DOI 10.1097/SIH.0B013E31818B27A8
[3]   THE STATIC ELASTIC PROPERTIES OF 45 HUMAN THORACIC AND 20 ABDOMINAL AORTAS INVITRO AND THE PARAMETERS OF A NEW MODEL [J].
LANGEWOUTERS, GJ ;
WESSELING, KH ;
GOEDHARD, WJA .
JOURNAL OF BIOMECHANICS, 1984, 17 (06) :425-435
[4]   ESTIMATION OF TOTAL SYSTEMIC ARTERIAL COMPLIANCE IN HUMANS [J].
LASKEY, WK ;
PARKER, HG ;
FERRARI, VA ;
KUSSMAUL, WG ;
NOORDERGRAAF, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (01) :112-119
[5]  
Latson T. W., 1987, VENTRICULAR VASCULAR, P334
[6]   EFFECT OF NITROGLYCERIN ON AORTIC IMPEDANCE, DIAMETER, AND PULSE-WAVE VELOCITY [J].
LATSON, TW ;
HUNTER, WC ;
KATOH, N ;
SAGAWA, K .
CIRCULATION RESEARCH, 1988, 62 (05) :884-890
[7]   ESTIMATION OF TOTAL ARTERIAL COMPLIANCE - AN IMPROVED METHOD AND EVALUATION OF CURRENT METHODS [J].
LIU, ZR ;
BRIN, KP ;
YIN, FCP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (03) :H588-H600
[8]   INPUT IMPEDANCE OF SYSTEMIC CIRCULATION [J].
OROURKE, MF ;
TAYLOR, MG .
CIRCULATION RESEARCH, 1967, 20 (04) :365-&
[9]   SYSTEMIC COMPLIANCE - DOES IT PLAY A ROLE IN THE GENESIS OF ESSENTIAL-HYPERTENSION [J].
RANDALL, OS ;
VANDENBOS, GC ;
WESTERHOF, N ;
POT, FOM .
CARDIOVASCULAR RESEARCH, 1984, 18 (08) :455-462
[10]  
RANDALL OS, 1976, NZ J MED S2, V6, P49