HOW CAN THE ASSESSMENT OF THE HEMODYNAMIC SIGNIFICANCE OF AORTOILIAC ARTERIAL-STENOSIS BY DUPLEX SCANNING BE IMPROVED - A COMPARATIVE-STUDY WITH INTRAARTERIAL PRESSURE MEASUREMENT

被引:20
作者
LEGEMATE, DA
TEEUWEN, C
HOENEVELD, H
EIKELBOOM, BC
机构
[1] ST ANTONIUS HOSP, DEPT VASC SURG, NIEUWEGEIN, NETHERLANDS
[2] ST ANTONIUS HOSP, DEPT RADIOL, NIEUWEGEIN, NETHERLANDS
[3] ST ANTONIUS HOSP, VASC LAB, NIEUWEGEIN, NETHERLANDS
关键词
D O I
10.1016/0741-5214(93)90110-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The current diagnostic criteria used to assess the severity of stenoses in the aortoiliac arteries by duplex scanning are mainly based on information related to changes in cross-sectional area and are flow independent. Consequently, duplex scanning fails to detect approximately one quarter of hemodynamically significant aortoiliac lesions compared with intraarterial pressure measurements. The aim of this study is to improve the assessment of the hemodynamic significance of aortoiliac lesions by duplex scanning. Methods: A prospective study in 60 patients was performed in which duplex scanning at rest was compared with intraarterial pressure measurements before and after the administration of papaverine. A simplified Bernoulli equation was used to calculate pressure gradients across stenoses (DELTAP(Bern)). Two flow-related parameters, the increase in peak systolic velocity (DELTAPSV) across the stenosis and the end-diastolic velocity at the site of the stenosis, were also measured and compared with intraarterial pressure measurements. Results: DELTAP(Bern) and DELTAPSV showed a sensitivity and specificity of 81% and 88%, respectively, for the detection of hemodynamically significant lesions at rest. However, DELTAP(Bern) could often not give an accurate calculation of the pressure gradient. Receiver operator characteristic analysis showed that a cut-off level for DELTAPSV in the range of 1.4 to 1.5 m/s was best able to detect significant lesions at rest. The end-diastolic velocity parameter had a limited diagnostic value. Conclusion: Although useful in clinical decision making, DELTAP(Bern) often could not give an accurate calculation of the pressure gradient. DELTAPSV is a simple and practical spectral analysis parameter to differentiate between significant and insignificant stenoses. This parameter also has the potential to detect hemodynamically less critical lesions if duplex scanning is performed under conditions of increased flow. Further evaluation is needed.
引用
收藏
页码:676 / 684
页数:9
相关论文
共 27 条
[1]  
ARCHIE JP, 1981, SURGERY, V90, P876
[2]  
Baker A R, 1987, Eur J Vasc Surg, V1, P273, DOI 10.1016/S0950-821X(87)80079-8
[3]   THE ACCURACY OF PULL-THROUGH PRESSURE MEASUREMENTS AND PAPAVERINE TESTING [J].
BAKER, AR ;
EVANS, DH ;
TAYLOR, JD ;
JAMES, DC ;
BELL, PRF .
ANGIOLOGY, 1985, 36 (09) :638-645
[4]   FEMORAL-ARTERY PRESSURE MEASUREMENT DURING AORTOGRAPHY [J].
BREWSTER, DC ;
WALTMAN, AC ;
OHARA, PJ ;
DARLING, RC .
CIRCULATION, 1979, 60 (02) :I120-I124
[5]  
BURNS PN, 1988, CLIN APPL DOPPLER UL, P56
[6]  
de Smet A A, 1990, Eur J Vasc Surg, V4, P275, DOI 10.1016/S0950-821X(05)80207-5
[7]   AORTOFEMORAL OR FEMOROPOPLITEAL REVASCULARIZATION - A PROSPECTIVE EVALUATION OF THE PAPAVERINE TEST [J].
FLANIGAN, DP ;
RYAN, TJ ;
WILLIAMS, LR ;
SCHWARTZ, JA ;
GRAY, B ;
SCHULER, JJ .
JOURNAL OF VASCULAR SURGERY, 1984, 1 (01) :215-223
[8]  
FLANIGAN DP, 1977, ANN SURG, V186, P663
[10]  
HATLE L, 1978, BRIT HEART J, V40, P131