A COLUMN GENERATION METHOD FOR OPTIMAL LOAD MANAGEMENT VIA CONTROL OF ELECTRIC WATER-HEATERS

被引:40
作者
LAURENT, JC [1 ]
DESAULNIERS, G [1 ]
MALHAME, RP [1 ]
SOUMIS, F [1 ]
机构
[1] ECOLE POLYTECH,DEPT APPL MATH,MONTREAL,PQ H3C 3A7,CANADA
关键词
D O I
10.1109/59.466513
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electric water heaters have been the focus of several previous studies where they are viewed as energy storing devices to be considered for peak load shaving within device interruption based load management programs. It is well known that such controls, when applied indiscriminately, can cause payback phenomena which could actually worsen existing peak loads. Thus, optimal switching strategies must be devised. A column generation based optimization scheme which combines the advantages of linear programming and dynamic programming approaches, both previously proposed in the load management literature, is presented. The method is successfully tested on a representative set of residential electric water heating load mixes. The results are analyzed in the paper, both from the computational and load management point of view.
引用
收藏
页码:1389 / 1400
页数:12
相关论文
共 14 条
[1]  
ALVAREZ C, WIN IEEE POW M
[2]  
BISCKE RF, 1985, IEEE T POWER APP SYS, V104
[3]  
BRADLEY SP, APPLIED MATH PROGRAM
[4]  
CHONG CY, 1979, P IEEE C DECISION CO
[5]  
COHEN AI, 1988, IEEE T POWER APP SYS, V3
[6]  
DESROSIERS J, IN PRESS HDB OPERATI
[7]  
GUSTAFSON MW, 1992, WIN IEEE POW M
[8]  
HASTINGS BF, 1980, IEEE T POWER APP SYS, V99
[9]  
KEMPTON W, 1988, ENERGY, V13
[10]  
LAURENT JC, 1993, SUM IEEE POW M VANC