TIBIAL SHOCK MEASURED WITH BONE AND SKIN MOUNTED TRANSDUCERS

被引:71
作者
LAFORTUNE, MA
HENNING, E
VALIANT, GA
机构
[1] UNIV ESSEN GESAMTHSCH,BIOMECAN LAB,D-43000 ESSEN,GERMANY
[2] NIKE INC,SPORTS RES LAB,BEAVERTON,OR
关键词
TIBIAL SHOCK; SKIN; BONE; RUNNING; TRANSFER FUNCTION; ACCELERATION;
D O I
10.1016/0021-9290(94)00150-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to assess the value of superficial transducer mounting to measure tibial shock during locomotion. Surface (SMT) and bone mounted transducers (BMT) simultaneously recorded axial tibial acceleration in five subjects who ran at 4.5 ms(-1). SMT produced inconsistent recording across the subjects both in the time and frequency domains. In two subjects, SMT signals provided close approximation of BMT signals, some distortion occurred in one subject while severe distortions were observed in the other two subjects. The present results established that SMT could not be used directly to quantify the shock transmitted through the tibia during running. However, frequency transformation of SMT recordings produced encouraging results; the transformed SMT signals mimicked the signals recorded with the bone mounted transducer.
引用
收藏
页码:989 / 993
页数:5
相关论文
共 10 条
[1]  
FREDERICK EC, 1984, SPORT SHOES PLAYING, P190
[2]  
GROSS TS, 1988, MED SCI SPORT EXER, V20, P506
[3]   MEASUREMENT OF THE IMPULSIVE BONE MOTION BY SKIN-MOUNTED ACCELEROMETERS [J].
KIM, W ;
VOLOSHIN, AS ;
JOHNSON, SH ;
SIMKIN, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (01) :47-52
[4]   3-DIMENSIONAL ACCELERATION OF THE TIBIA DURING WALKING AND RUNNING [J].
LAFORTUNE, MA .
JOURNAL OF BIOMECHANICS, 1991, 24 (10) :877-886
[5]  
LAFORTUNE MA, 1991, MED SCI SPORT EXER, V23, P360
[6]   CUSHIONING PROPERTIES OF FOOTWEAR DURING WALKING - ACCELEROMETER AND FORCE PLATFORM MEASUREMENTS [J].
LAFORTUNE, MA ;
HENNIG, EM .
CLINICAL BIOMECHANICS, 1992, 7 (03) :181-184
[7]   SKELETAL TRANSIENTS ON HEEL STRIKE IN NORMAL WALKING WITH DIFFERENT FOOTWEAR [J].
LIGHT, LH ;
MCLELLAN, GE ;
KLENERMAN, L .
JOURNAL OF BIOMECHANICS, 1980, 13 (06) :477-480
[8]   EFFECT OF SOFT-TISSUE ON WAVE-PROPAGATION AND VIBRATION TESTS FOR DETERMINING INVIVO PROPERTIES OF BONE [J].
SAHA, S ;
LAKES, RS .
JOURNAL OF BIOMECHANICS, 1977, 10 (07) :393-401
[9]  
VALIANT GA, 1987, BIOMECHANICS B, V10, P937
[10]   EFFECT OF SOFT-TISSUE ON MEASUREMENTS OF VIBRATIONAL BONE MOTION BY SKIN-MOUNTED ACCELEROMETERS [J].
ZIEGERT, JC ;
LEWIS, JL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1979, 101 (03) :218-220