MAGNETIC-RESONANCE-IMAGING OF ABSCESSES USING LIPID-COATED IRON-OXIDE PARTICLES

被引:17
作者
CHAN, TW
ELEY, C
LIBERTI, P
SO, A
KRESSEL, HY
机构
[1] HOSP UNIV PENN,DEVON MRI CTR,DEPT RADIOL,PHILADELPHIA,PA 19104
[2] VESTAR INC,SAN DIMAS,CA
[3] IMMUNICON CORP,HUNTINGDON VALLEY,PA
[4] CHESTNUT HILL HOSP,DEPT HEMATOL & PATHOL,PHILADELPHIA,PA
关键词
ABSCESS; IRON OXIDE; MAGNETIC RESONANCE CONTRAST;
D O I
10.1097/00004424-199206000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigated whether iron oxide particles can be used as a magnetic resonance imaging (MRI) contrast agent to image abscesses in a two-stage experimental design. METHODS. Human buffy coat was incubated with iron oxide particles of different sizes and coatings. Smears of the incubation mixture were made on a glass slide and stained for iron. The percentage of iron oxide uptake was determined by counting 100 neutrophils and monocytes and scoring the number of cells that contain iron. Subcutaneous abscesses were created in the flanks of 18 Sprague-Dawley rats by injecting them with 0.1 mL of turpentine. Iron oxide was given intravenously, and the animals were imaged by MRI (1.5 T) 12 to 24 hours later. Different iron oxide coatings and doses were compared. RESULTS. The four different types of coating (constant fragment [Fc] of IgG, bovine serum albumin [BSA], lipid [Ferrosome], and dextran) had an uptake of 72% +/- 5.3%, 61% +/- 6.2%, 30.5% +/- 6.8%, and 5% +/- 2.5%, respectively. Comparison of two particle sizes (mean, 90 versus 35 nm) showed the large particles to have higher uptake (61% +/- 6.2%) compared with the small particles (6% +/- 1.8%) (P < .001). Post-contrast imaging of the rats showed a hypointense ring around the abscess only in the animals injected with the lipid-coated agent. The effect was discernible within 12 hours after contrast injection and at a dose of 25-mu-mol iron/kg. Histologic sections showed phagocytic cells with iron granules in the periphery of the abscess. No hypointense ring on MRI or iron granules on histologic sections was seen around the abscess of the control animals or those injected with BSA-iron oxide or Fc-iron oxide. CONCLUSIONS. Lipid-coated iron oxide particles can be used to image abscesses by virtue of their phagocytosis into surrounding inflammatory cells. Positive uptake of these particles by human phagocytes in vitro suggests that similar results may he applicable in humans.
引用
收藏
页码:443 / 449
页数:7
相关论文
共 21 条
  • [1] CONCANAVALIN-A-MEDIATED ATTACHMENT AND INGESTION OF YEAST-CELLS BY MACROPHAGES
    BARSHAVIT, Z
    GOLDMAN, R
    [J]. EXPERIMENTAL CELL RESEARCH, 1976, 99 (02) : 221 - 236
  • [2] CHARACTERIZATION AND INVIVO DISTRIBUTION OF TC-99M-LABELED AND IN-111-LABELLED MAGNETITE
    BLIGH, SWA
    SADLER, PJ
    MARRIOTT, JA
    LATHAM, IA
    KELLY, JD
    [J]. APPLIED RADIATION AND ISOTOPES, 1989, 40 (09) : 751 - 757
  • [3] CHAN TW, 1991, MR IMAGING ABSCESS T, P54
  • [4] MAGNETOLIPOSOMES - FORMATION AND STRUCTURAL CHARACTERIZATION
    DECUYPER, M
    JONIAU, M
    [J]. EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 1988, 15 (05): : 311 - 319
  • [5] DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS
    EDELMAN, RR
    SIEGEL, JB
    SINGER, A
    DUPUIS, K
    LONGMAID, HE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) : 1213 - 1219
  • [6] ELEY CGS, 1988, Patent No. 87311040
  • [7] TRANSVERSE RELAXATION RATE ENHANCEMENT CAUSED BY MAGNETIC PARTICULATES
    HARDY, PA
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IMAGING, 1989, 7 (03) : 265 - 275
  • [8] HARRIS WE, 1974, CHEM SEPARATIONS MEA, P152
  • [9] HESSELINK JR, 1988, RADIOL CLIN N AM, V26, P873
  • [10] LIBERTI PA, 1991, CELL SEPARATION SCI, P268