INDIRECT DETERMINATION OF SULFATE BY ATOMIC-ABSORPTION SPECTROPHOTOMETRY

被引:3
作者
CHANG, CM [1 ]
HUANG, HJ [1 ]
机构
[1] NATL SUN YAT SEN UNIV,DEPT CHEM,KAOHSIUNG 80424,TAIWAN
关键词
BARIUM SULFATE; FLOW-INJECTION TECHNIQUE; MIXED SOLVENT;
D O I
10.1002/jccs.199300067
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
With a flow injection technique, the content of sulfate in solution was determined indirectly from the concentration of partially equilibrated barium ion in solution. To obtain improved sensitivity, atomic absorption spectrophotometry of a flame was used to determine barium. With these procedures combined with a linear calibration graph, superior sensitivity and detection limit of sulfate determination were obtained compared with those from other indirect methods.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 17 条
[1]  
BELCHER R, 1977, MIKROCHIM ACTA, V11, P81
[2]  
BORDEN IY, 1970, SOIL SCI SOC AM J, V34, P705
[4]   DETERMINATION OF SULFATE, ORTHO-PHOSPHATE, AND TRIPHOSPHATE IONS BY FLOW-INJECTION ANALYSIS WITH THE LEAD ION-SELECTIVE ELECTRODE AS DETECTOR [J].
COETZEE, JF ;
GARDNER, CW .
ANALYTICAL CHEMISTRY, 1986, 58 (03) :608-611
[5]   INDIRECT ANALYSES OF SULFATE IN BRINES BY ATOMIC-ABSORPTION [J].
COUTO, MI ;
CURTIUS, AJ .
APPLIED SPECTROSCOPY, 1980, 34 (02) :228-229
[6]  
COUTO MI, 1980, APPL SPECTROSC, V34, P229
[7]   DETERMINATION OF MICROGRAM AMOUNTS OF SULFATE BY EMISSION-SPECTROSCOPY OF BARIUM WITH A NITROUS OXIDE-ACETYLENE FLAME [J].
FORBES, EA .
ANALYST, 1973, 98 (1168) :506-511
[8]  
GALLE DK, 1975, APPL SPECTROSC, V29, P518
[9]  
Hoare, 1969, ATOM ABSORPT NEWSL, V8, P79
[10]   BARIUM ION-SLECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER COMPLEX [J].
LEVINS, RJ .
ANALYTICAL CHEMISTRY, 1971, 43 (08) :1045-&