EFFECTS OF AORTIC BALLOON PUMPING DURING CARDIOPULMONARY BYPASS ON MYOCARDIAL PERFUSION, METABOLISM, AND CONTRACTILITY

被引:9
作者
GROVER, FL
FEWEL, JG
VINAS, J
GHIDONI, JJ
AROM, KV
NORTON, JB
TRINKLE, JK
机构
[1] AUDIE L MURPHY VET ADM HOSP,CARDIOTHORAC SURG SECT,SAN ANTONIO,TX
[2] UNIV TEXAS,HLTH SCI CTR,SAN ANTONIO,TX 78284
关键词
D O I
10.1378/chest.75.1.37
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
This study was undertaken to determine if the production of pulsatile flow by the intra-aortic balloon pump during cardiopulmonary bypass had any beneficial effect on coronary flow, regional myocardial flow, myocardial metabolism, and left ventricular function. Thirty-six conditioned dogs were subjected to one hour of total normothermic cardiopulmonary bypass. They were divided into the following five groups: (1) controls, beating heart and femoral inflow; (2) balloon, beating heart and femoral inflow; (3) balloon, beating heart, and aortic inflow; (4) control, fibrillating heart and femoral inflow; and (5) balloon, fibrillating heart, and femoral inflow. Total coronary flow, left ventricular flow, coronary sinus flow and the endocardial-to-epicardial flow ratio increased in Group 3. This increase in flow may have been in part due to increased resistance to flow in the descending aorta by the balloon. No differences in flow were noted in the other groups, all of which were perfused via the femoral artery. No significant differences in myocardial metabolism or left ventricular contractility could be demonstrated between balloon-treated and control groups in these normal hearts.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 12 条
[1]  
Gill C C, 1973, Ann Thorac Surg, V16, P445
[2]   CARDIOVASCULAR RESPONSES TO DIASTOLIC AUGMENTATION IN INTACT CANINE CIRCULATION AND AFTER LIGATION OF ANTERIOR DESCENDING CORONARY ARTERY [J].
GOLDFARB, D ;
BROWN, BG ;
CONTI, CR ;
GOTT, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 55 (02) :243-&
[3]   IMPROVED ORGAN FUNCTION DURING CARDIAC BYPASS WITH A ROLLER PUMP MODIFIED TO DELIVER PULSATILE FLOW [J].
JACOBS, LA ;
KLOPP, EH ;
SEAMONE, W ;
TOPAZ, SR ;
GOTT, VL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (05) :703-+
[4]  
Lowry O.H., 1972, FLEXIBLE SYSTEM ENZY
[5]   EFFECT OF PULSATILE AND NON-PULSATILE FLOW DURING CARDIOPULMONARY BYPASS ON LEFT-VENTRICULAR EJECTION FRACTION EARLY AFTER AORTOCORONARY BYPASS SURGERY [J].
MADDOUX, G ;
PAPPAS, G ;
JENKINS, M ;
BATTOCK, D ;
TROW, R ;
SMITH, SC ;
STEELE, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (07) :1000-1006
[6]  
PAPPAS G, 1975, SURGERY, V77, P34
[7]   SIMPLE METHOD OF PRODUCING PULSATILE FLOW DURING CLINICAL CARDIOPULMONARY BYPASS [J].
PAPPAS, G .
ANNALS OF THORACIC SURGERY, 1974, 17 (04) :405-406
[8]   EFFECTS OF INTRA-AORTIC BALLOON COUNTERPULSATION ON CARDIAC PERFORMANCE, OXYGEN CONSUMPTION, AND CORONARY BLOOD FLOW IN DOGS [J].
POWELL, WJ ;
DAGGETT, WM ;
MAGRO, AE ;
BIANCO, JA ;
BUCKLEY, MJ ;
SANDERS, CA ;
KANTROWITZ, AR ;
AUSTEN, WG .
CIRCULATION RESEARCH, 1970, 26 (06) :753-+
[9]   RELATION OF PULSATILE FLOW TO OXYGEN CONSUMPTION AND OTHER VARIABLES DURING CARDIOPULMONARY BYPASS [J].
SHEPARD, RB ;
KIRKLIN, JW .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (05) :694-&
[10]  
TRINKLE JK, 1969, J THORAC CARDIOV SUR, V58, P562