摘要
From a study of 526 patients having automatic ECG analysis, criteria were established which diagnosed acute evolving Q wave myocardial infarction with 71% sensitivity and 98% specificity. Specificity was 100% when patients with known previous Q wave infarction were excluded. In pre-hospital practice the high sensitivity and specificity were maintained. This method appears appropriate, when other criteria are met, for paramedic-initiated pre-hospital thrombolysis with remote supervision of a cardiologist by telephone.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 15 条
[1]  
BETT J H N, 1989, Australian and New Zealand Journal of Medicine, V19, P572
[2]  
BOUTEN M, 1990, NED TIJDSCHR GENEESK, P2434
[3]  
GREENBERG H, 1988, LANCET, V2, P1187
[4]  
KENNEDY JW, 1990, CLIN CARDIOL, V13, P23
[5]  
KUDENCHUK PJ, 1989, CIRCULATION S2, V80, P354
[6]  
MANTELL SJ, 1989, CIRCULATION, V80, P391
[7]   LIMITATION OF MYOCARDIAL-INFARCTION BY EARLY INFUSION OF RECOMBINANT TISSUE-TYPE PLASMINOGEN-ACTIVATOR [J].
OROURKE, M ;
BARON, D ;
KEOGH, A ;
KELLY, R ;
NELSON, G ;
BARNES, C ;
RAFTOS, J ;
GRAHAM, K ;
HILLMAN, K ;
NEWMAN, H ;
HEALEY, J ;
WOOLRIDGE, J ;
RIVERS, J ;
WHITE, H ;
WHITLOCK, R ;
NORRIS, R .
CIRCULATION, 1988, 77 (06) :1311-1315
[8]  
ROURKE MF, 1990, AUST NZ J MED, V20, P329
[9]  
SHARKEY SW, 1989, CIRCULATION, V80, P353
[10]  
SIMOONS M, 1989, THROMBOLYSIS CARDIOV, P87