EVALUATION OF A DIGITAL WORKSTATION FOR INTERPRETING NEONATAL EXAMINATIONS - A RECEIVER OPERATING CHARACTERISTIC STUDY

被引:40
作者
FRANKEN, EA [1 ]
BERBAUM, KS [1 ]
MARLEY, SM [1 ]
SMITH, WL [1 ]
SATO, Y [1 ]
KAO, SCS [1 ]
MILAM, SG [1 ]
机构
[1] UNIV IOWA,DEPT RADIOL,IOWA CITY,IA 52242
关键词
OBSERVER PERFORMANCE; PICTURE ARCHIVING COMMUNICATION SYSTEM; PSYCHOPHYSICS; VISUAL PERCEPTION;
D O I
10.1097/00004424-199209000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The purpose of this study is to compare the diagnostic accuracy of interpreting clinical neonatal radiographs using a commercially available digital workstation versus conventional radiographic images. METHODS. The case sample consists of 100 chest or abdominal radiographs from the neonatal intensive care unit in which diagnosis was confirmed. Four radiologists served as observers. During two initial reading sessions, half of the studies were viewed on digital radiography monitors and the other half by plain film. Observers indicated whether each patient had normal or abnormal findings and their degree of confidence in this judgment. Six weeks later, observers viewed cases on the alternate presentation system. Two statistical analyses were performed: the data from each observer were treated as a separate experiment in the first analysis; the data from all observers were combined using a new method in the second analysis. RESULTS. No differences between areas under receiver operating characteristic (ROC) curves for viewing on the picture archiving and communication system (PACS) console and plain film were found for any observer (0.86 versus 0.86, 0.89 versus 0.86, 0.88 versus 0.85, 0.83 versus 0.82). CONCLUSIONS. The study suggests that for pediatric plain film images, video images offer diagnostic information comparable with that of conventional radiographs for neonatal examinations.
引用
收藏
页码:732 / 737
页数:6
相关论文
共 9 条
  • [1] MEASURING OBSERVER PERFORMANCE BY ROC ANALYSIS - INDICATIONS AND COMPLICATIONS
    BERBAUM, KS
    DORFMAN, DD
    FRANKEN, EA
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (03) : 228 - 233
  • [2] MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA
    DORFMAN, DD
    ALF, E
    [J]. JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) : 487 - &
  • [3] RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD
    DORFMAN, DD
    BERBAUM, KS
    METZ, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (09) : 723 - 731
  • [4] COMPARISON OF A PACS WORKSTATION WITH CONVENTIONAL FILM FOR INTERPRETATION OF NEONATAL EXAMINATIONS - A PAIRED COMPARISON STUDY
    FRANKEN, EA
    SMITH, WL
    BERBAUM, KS
    KAO, SCS
    SATO, Y
    [J]. PEDIATRIC RADIOLOGY, 1991, 21 (05) : 336 - 340
  • [5] DIGITAL IMAGING OF THE CHEST
    FRASER, RG
    SANDERS, C
    BARNES, GT
    MACMAHON, H
    GIGER, ML
    DOI, K
    TEMPLETON, AW
    COX, GG
    DWYER, SJ
    MERRITT, CRB
    JONES, JP
    [J]. RADIOLOGY, 1989, 171 (02) : 297 - 307
  • [6] ANALYSIS OF THE COST-EFFECTIVENESS OF PACS
    HILSENRATH, PE
    SMITH, WL
    BERBAUM, KS
    FRANKEN, EA
    OWEN, DA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) : 177 - 180
  • [7] STATISTICAL SIGNIFICANCE TESTS FOR BINORMAL ROC CURVES
    METZ, CE
    KRONMAN, HB
    [J]. JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1980, 22 (03) : 218 - 243
  • [8] METZ CE, 1984, INFORMATION PROCESSI, P432
  • [9] Metz CE, 1986, MULTIPLE REGRESSION, P365