During measurements of airborne sound insulation between domestic-sized rooms, anomalies were found in insulation values measured under what were thought to be identical measuring conditions. Further investigation has shown that these anomalies were due to temperature differences between the source and receiving rooms. The note gives an account of this work. © 1969.